Message Type; Get Current Parameter From A Monitor - NEC X754HB Manual

Hide thumbs Also See for X754HB:
Table of Contents

Advertisement

5. Message type

5.1 Get current Parameter from a monitor.

STX
OP code
page
Hi
st
nd
1
2
-3
Send this message when you want to get the status of a monitor.
For the status that you want to get, specify the "OP code page" the "OP code", refer to "Appendix
A. Operation code table".
st
1
byte) STX: Start of Message
ASCII STX (02h)
nd
rd
2
-3
bytes) OP code page: Operation code page.
Specify the "OP code page" for the control which you want to get the status.
Refer to "Appendix A Operation code table" for each item.
OP code page data must be encoded to ASCII characters.
Ex.) The byte data 02h must be encoded to ASCII characters '0' and '2' (30h and 32h).
OP code page 02h ->
Refer to Operation code table. (Appendix A)
th
th
4
–5
bytes) OP code: Operation code
Refer to "Appendix A Operation code table" for each item.
OP code data must be encoded to ASCII characters.
Ex.) The byte data 3Ah must be encoded to ASCII characters '3' and 'A' (33h and 41h).
OP code 3Ah ->
Refer to Operation code table.
th
6
byte) ETX: End of Message
ASCII ETX (03h)
OP code
ETX
Lo
Hi
Lo
rd
th
th
4
–5
OP code page (Hi) = ASCII '0' (30h)
OP code page (Lo) = ASCII '2' (32h)
OP code (Hi) = ASCII '3' (33h)
OP code (Lo) = ASCII 'A' (41h)
th
6
(15/139)