HANDLE ADJUSTMENT

1. Loosen handle adjustment lock lever and adjust handle to comfortable
operation height
2. Tighten lever to lock handle in place.

BAG INSTALLATION

1. Position the handle in normal operating position.
2. Open bag compartment lid and rest it on the handle.
3. Unzip cloth bag and install paper bag inside.
4. Attach both bag openings together onto vacuum intake housing.
5. Make sure bag is properly positioned inside machine housing.
6. Completely close zipper on cloth bag and close lid of machine.
ATTENTION: Always use cloth and paper bags together.

BRUSH HEIGHT ADJUSTMENT

1. This machine has 5 brush adjustment levels.
2. To raise brush height level: lift up height adjustment pedal until
desired brush height is attained.
3. To lower brush height level: push down on height adjustment pedal
until desired brush height is attained.

OPERATION OF MACHINE

1. Plug power cord into properly grounded power outlet.
2. Push the on/off switch to the ON (I) position.
3. To operate brush squeeze the brush start triggers.
4. Push machine forward to begin cleaning.
5. Adjust brush height for proper pick-up.
CIRCUIT BREAKER PROTECTION
Your new wide area vacuum comes equipped with two manual circuit
breakers, a 15 amp breaker for the vacuum motor and a 2.5 amp breaker
for the brush motor. If the machine does not turn on you will need to
check the circuit breakers.
To reset circuit breakers:
1. Turn off and unplug the vacuum cleaner.
2. Check machine for the following:
Full bag, obstructions, clogged filters, clogged brush, brush
height set too low, etc.
3. Press the affected circuit breaker button to reset.
4. Resume operation
If vacuum cleaner fails to turn on, contact a Tennant or Nobles
Authorized Service Center or Distributor.

FOR BEST PERFORMANCE

• Keep machine and all accessories clean and in good operating
condition.
• Change vacuum bags and filters as recommended to maintain
optimum cleaning efficiency.
• Always use OEM bags, filters and parts, as use of other products
may result in poor cleaning of filtration performance. OEM products
are designed for maximum performance.
• Have machine checked periodically by a Tennant or Nobles Autho-
rized Service Center or Distributor.
• Store machine carefully in a dry area.
• For optimum cleaning performance and safety, follow your owner's
manual.
• After each use, carefully wrap power cord around handle and check
cord for wear or damage. If cord is damaged, have power cord
replaced by a Tennant or Nobles Authorized Service Center or
Distributor immediately.