Auger Motor

1. Before beginning any component replacement, be certain the unit is unplugged and thoroughly
cooled down. Also, make sure the hopper is empty before attempting to remove or replace the
auger motor assembly.
2. Remove the back panel of the unit, using a
bolts, detach the wiring harness from the auger motor.
3. Locate the auger motor assembly at the rear of the stove, and begin by loosening the two
allen set screws on either side of the cast iron auger motor coupler.
4. Slide the auger assembly out of the tube.
5. Next, remove the four screws which hold the cast iron auger motor coupler to the auger motor,
5
using a
/
" wrench. Slide the cast iron auger motor coupler and the steel spacer plate off of
16
the auger motor.
1
6. Loosen the
/
8
shaft, and remove the steel auger coupler, as well as the rubber vibration dampener.
7. Reinstall the parts in reverse order on the new auger motor, being careful not to over-tighten
the bolts which hold the cast iron auger coupler to the auger motor.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY

REPLACING COMPONENTS

" allen set screw which holds the steel auger coupler to the auger motor output
5
/
" wrench. Before loosening any auger motor
16
34