Firmware Upgrade For Cpu - Philips 190CW7CS/00 Service Manual

Hide thumbs Also See for 190CW7CS/00:
Table of Contents

Advertisement

3
Press the AUTO to running program , the firmware be updated
as shown in Fig. 9~10.
4
Press the file --> exit to end program , as shown in Fig. 11.

Firmware Upgrade for CPU

Fig. 8
Fig. 9
Fig. 10
Fig. 11
If there is a warring message coming as shown in Fig 12. , you
have to check the AC power, Video cable, or Novatek MCU.
5 Check the firmware version
1). Turn off monitor.
2).
[Push "AUTO" & "MENU" buttons at the same time and hold them]
+[Press "power" button untill comes out "Windows screen" ]
=> then release all buttons.
3).Press "MENU" button, wait until the OSD menu come on the
Screen of the monitor.You will find, after upgrade, the version
have already changed from The former"HUDSON 190CW7
V0.06 2006-06-01" to the Present "HUDSON 190CW7 V0.15
2006-06-26 as shown in Fig. 13 and Fig. 14.
Factory Mode indicator
Factory Mode indicator
4) Turn off the monitor, exit the factory mode.
190CW7 LCD
27
Fig. 12
Fig. 13
Fig. 14