Firmware Upgrade For Cpu; Isp Instruction - Philips 200P7ES/00 Service Manual

20.1" lcd monitor
Hide thumbs Also See for 200P7ES/00:
Table of Contents

Advertisement

Configuration and procedure
"Easywriter " The software
is provided by Novatek to upgrade the
firmware of CPU.
It is a windows-based program, which cannot be run in MS-DOS.
The tool (3138 106 10396)
is for the interface between "Parallel Port of
PC" and "15 pin-D-SUB connector of Monitor".
System and equipment requirements
1.
An i486 (or above) personal computer or compatible.
2.
Microsoft operation system Windows 95/98/2000/XP.
3.
ISP Software " Easywrite "
4.
ISP
TOOL (3138 106 10396)
5
.
Connect
ISP TOOL
and Mains cord to Monitor as shown
in Fig. 2.
Monitor (A)
Connect to
Mains cord
Video cable
6. Run the Easywriter program
Step 1 : Make a folder in your PC as shown in Fig. 3.
For example : C:\easywrite
Step 2 : Copy ISP Software Easywriter
as shown in Fig.3.
Step 3 : Unzip Easywriter.zip into your folder as shown in Fig. 3.
Step 4 : Double click the EasywriterV2.09.exe icon to run the
Application as Fig. 4.

ISP Instruction

as shown in Fig. 1
Fig. 1
PC
200P7 LCD (B)
D-Sub
AC POWER
DC 8-12V
+
To
Port
ToPC
313810610396
.zip
into your folder
Fig. 3
Double click the shortcut
Step 5 :Copy the .hex code to C:\200P7 as shown in Fig. 5 .
Update the firmware
1. Press the load hex then select the .hex code as shown in Fig.6
2. Press the AUTO to run the program,the firmware be updated as
shown in Fig7`Fig.8
Novatek EasyWriter 2.09
Information file(ezwriter.ini) V1.0
Load File
C:\ 200P7\313811709301_141_9E83.hex
HexFile Check Sum :BAC2
C:\ 200P7\313811709301_141_9E83.hex
NT68F632A/631A Detected
Chip erase OK
Programing Success!!!
ISP OFF.
- Auto process Finished -
200P7 LCD
Go to cover page
on the desktop
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig.8
29

Advertisement

Table of Contents
loading

Table of Contents