7.4 Sunny Boy 1700 Operating parameters

Unauthorised changes to the operating parameters may result in:
• Injury or accidents as a result of changing the internal safety
routines in the Sunny Boy
• Voiding the Sunny Boy's operating permission
• Voiding the Sunny Boy's guarantee
Never change the parameters of your Sunny Boy without express
authorization and instructions.
The parameters with a grey background are only visible when in installer mode.
Name
Betriebsart /
Operating mode
Default
dFac-Max
dZac-Max
E_Total
Fac-Delta-
Fac-Delta+
h_Total
I-NiTest / Testcurrent Zac
Speicherfunktion /
Memory function
Speicher / Storage
T-Start
T-Stop
Uac-Min / Vac-Min
Uac-Max / Vac-Max
Upv-Start / Vpv-Start
Usoll-Konst / Vconst-Setpoint
Installation Guide
Unit
Value range
MPP, IKonst, UKonst, Stopp,
Turbine Mode, Insel Mode
Hz/s
0.005 ... 4.0
mOhm
0 ... 20000
kWh
0 ... 200000
Hz
Hz
h
0 ... 200000
mA
0 ... 8000
Default Parameter, Reset
Betriebsdaten, Reset Fehler
Permanent, volatile
s
s
1 ... 3600
V
180 ... 300
V
180 ... 300
V
150 ... 400
V
150 ... 430
0 ... 4.5
0 ... 4.5
5 ... 300
SB1700-11:SE2006
Technical data
Factory setting
MPP
GER/ENS
0,25
350
0,19
0,19
8000
none
Permanent
10
2
198
260
180
410