OBJ_DOKU-27402-001.fm Page 12 Thursday, July 14, 2011 10:43 AM
12 | English
13 On/Off and memory delete button
14 1/4" thread
15 Latch of battery lid
16 Battery lid
17 Serial number
18 Laser beam outlet
19 Reception lens
20 Tripod*
21 Laser viewing glasses*
22 Laser target plate*
23 Carrying strap*
24 Protective pouch
* The accessories illustrated or described are not included as
standard delivery.
Display Elements
a Battery indicator
b Temperature warning
c Measured value/result
d Unit of measure
e Measurement reference level
f Laser switched on
g Individual measured value (for length measurement:
result)
h Measuring functions
Length measurement
Tracking (continuous measurement)
Area measurement
Volume measurement
i Measured values stored

Technical Data

Digital Laser Rangefinder
Article number
Measuring range
Measuring accuracy (typically)
Lowest indication unit
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter (at 25 °C)
approx.
– at 10 m distance
– at 40 m distance
Batteries
Rechargeable batteries
Battery live, approximately
– Individual measurements
– Continuous measurement
2 609 140 582 | (14.7.11)
Digital Laser Rangefinder
Automatic switch-off after approx.
– Laser
– Measuring tool (without meas-
urement)
Weight according to
EPTA-Procedure 01/2003
Dimensions
Degree of protection (excluding
battery compartment)
A) The working range increases depending on how well the laser light is
reflected from the surface of the target (scattered, not reflective) and
with increased brightness of the laser point to the ambient light intensity
(interior spaces, twilight). In unfavourable conditions (e.g. when meas-
uring outdoors at intense sunlight), it may be necessary to use the target
plate.
B) In unfavourable conditions (e.g. at intense sunlight or an insufficient-
ly reflecting surface), the maximum deviation is
favourable conditions, a deviation influence of
taken into account.
C) In the continuous measurement function, the maximum operating
temperature is +40 °C.
D) Less measurements are possible when using 1.2 V rechargeable bat-
teries than with 1.5 V batteries.
Please observe the article number on the type plate of your measuring
tool. The trade names of the individual measuring tools may vary.
The measuring tool can be clearly identified with the serial number 17
on the type plate.
Assembly
Inserting/Replacing the Battery (see figure A)
DLE 40
Professional
Use only alkali-manganese or rechargeable batteries.
3 601 K16 300
Less measurements are possible when using 1.2 V recharge-
able batteries than with 1.5 V batteries.
A)
0.05–40 m
To open the battery lid 16, press the latch 15 in the direction
B)
±1.5 mm
of the arrow and remove the battery lid. Insert the batteries
1 mm
provided. Pay attention to the correct polarity of the batteries
C)
–10 °C...+50 °C
according to the representation in the battery compartment.
–20 °C...+70 °C
When the
90 %
first time, then at least 100 measurements are still possible.
The batteries must be replaced when the battery symbol
2
flashes; taking measurements is no longer possible.
635 nm, <1 mW
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
6 mm
not using it for extended periods. When storing for ex-
24 mm
tended periods, the batteries can corrode and discharge
4 x 1.5 V LR03 (AAA)
themselves.
4 x 1.2 V KR03 (AAA)
D)
30000
D)
5 h
58 x 100 x 32 mm
IP 54 (dust and splash
water protected)
±
10 mm per 40 m. In
±
0.05 mm/m must be
battery symbol appears in the display for the
Bosch Power Tools
DLE 40
Professional
20 s
5 min