Sony DVP-S335 Service Manual page 69

Cd/dvd player
Hide thumbs Also See for DVP-S335:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
Normally, all items are checked successively one after another au-
tomatically unless an error is found.
Selecting 2 and subsequent items executes respective menus and
outputs the results.
For the contents of each submenu, see "Check Items List".
General Description of Checking Method
2. Version
(2-2) Revision
ROM revision number is displayed.
Error: Not detected.
The revision number defined in the source file of ROM
(IC104) is displayed with four digits.
(2-3) ROM Check Sum
Check sum is calculated.
Error: Not detected.
The data are added of ROM (IC104) and the result is dis-
played with 4-digit hexadecimal number. Error is not de-
tected. Compare the result with the specified value.
(2-4) Model Type
Model code is displayed.
Error: Not detected.
The model code is displayed with 2-digit hexadecimal num-
ber.
DVP-S335 (AEP50, UK)
TE
L 13942296513
DVP-S335 (AEP51)
DVC-S335 (RU)
DVC-S335 (E, EA)
DVC-S336 (AEP06, UK)
DVC-S336 (AEP08)
DVC-S336 (AUS)
DVC-S345 (E)
DVP-S535D (AEP53, UK)
DVP-S535D (AEP52)
DVP-S735D (AEP51, UK)
DVP-S735D (AEP50)
DVP-S735D (RU)
DVP-S735D (E, EA)
DVP-S735D (AUS)
• Abbreviation
AUS
: Australian
EA
: Saudi Arabia
RU
: Russian
• Description about destination (AEP model)
AEP50
R
This number indicates the suffix
number of its "model code".
(2-5) Region
Region code is displayed.
www
Error: Not detected.
The region code determined from the model code is dis-
played.
.
http://www.xiaoyu163.com
Model Type
0
3
0
4
0
5
0
9
0
3
0
4
0
A
0
9
1
3
1
4
2
3
2
4
2
5
2
9
2
A
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
3. Peripheral
(3-2) EEPROM Check
Data write → read, and accord check
Error 03: EEPROM write/read discord
Before writing, the data are saved, then after checking, they
are written to restore the contents of EEPROM.
(3-3) Gate Array Check
Data write → read, and accord check
Error 02: Gate array write/read discord
(3-4) NAND Flash Check
Data clear → write → read, and accord check
This check is conducted to the DVP-S735D only.
Error 04: Clear error
05: Write error
06: Read data discord
21: Faulty blocks exceed 10
The data clear, write, read, and check are executed to the
block 0 of Flash memory (IC802).
In case of a faulty block, its address is displayed.
4. Servo
(4-2) Servo DSP Check
Data write → read, and accord check
Error 12: Read data discord
(4-3) DSP Driver Test
Test signal data → DSP Driver
Error: Not detected.
Q Q
3
6 7
1 3
1 5
5. Supply
Caution: Do not conduct this check with a mechanical deck con-
nected.
An access is made to the stream supply and servo con-
trol IC (IC302) and external RAM (IC303) using check
data. If mechanical deck is connected, the motor and
optics could be damaged. This check is also executed by
the "All" menu item.
Supplement: How to disconnect mechanical deck
Disconnect flexible flat cables connected to the
CN201 and CN202 of MB-86 board. Also, discon-
nect flat cable from the CN401.
(5-2) ARP Register Check
Data write → read, and accord check
Error 08: ARP register write, and read data discord
(5-3) ARP to RAM Data Bus
Data write → read, and accord check
Error 09: ARP ←→ RAM data bus error
Data 0x0001 to 0x8000 where one bit each is set to 1 are
written to the address 0 of RAM (IC303) connected to the
ARP (IC302) through the bus, then they are read and
checked. In case of discord, written bit pattern and read
data are displayed. If data where multiple bits are 1 are
read, the bits concerned may touch each other. Further, if
data where certain bit is always 1 or 0 regardless of written
data, the line could be disconnected or shorted.
co
(5-4) ARP to RAM Address Bus
Data write → other address read discord check
Error 10: ARP → RAM address bus error
.
Caution: Address and data display in case of an error is
different from the display of other diagnosis (de-
scribed later).
6-2
9 4
2 8
0 5
8
2 9
9 4
2 8
m
9 9
9 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents