FRONT ACCESS TO
(SIT) MILLIVOLT
FACE PLATE
CONTROL BRACKET
VALVE
When performing pressure checks or wiring
accessories such as remote control, or wall
mounting thermostats it will be necessary to
access the front of the valve body.
To access the front of the valve body, you
must remove the face plate from the control
bracket. To remove the face plate you will
need to remove the two (2) Phillip head
screws which attach it. After removing the
screws, pull the face plate back from the
unit. This will give you the access you need.
When finished reattach the face plate to the
control bracket with the screws you
re-
moved before operating the unit.
SCREWS
(SIT) MILLIVOLT VALVE WITH FACE PLATE ON
CAUTION
If unit has been in operation, allow the
unit time to cool before touching. Failure
to do so may result in personal injury.
NOTE: To ensure proper
connection of switch refer
to page 32. Make sure the
proper wires are used for
thermostat
and
remote
control connections, if not
installed correctly
the
unit will not operate.
(SIT MILLIVOLT VALVE WITHOUT FACE PLATE)