3. Measure up so there will be at least 1/4" rise per foot of horizontal connector pipe,
maintaining clearances to
of hole for chimney penetration.
4. After locating center of penetration, install
manufacturer's specifications.
5. Connect chimney connector to tee-box using #24 ga. minimum blue or black steel
connector pipe. DO NOT use galvanized pipe. Connect each section so crimped end
faces downward, and secure each section to each other using three (3) sheet metal screws or
rivets. (See Figure 10. Page 15).
C. Wall Exit Into Masonry Flue (Using Single Wall Pipe)
1. Before connecting these units to a masonry chimney, determine that masonry flue pass-
through connector thimble meets
a minimum of 18" from ceiling. If connector thimble does not meet these codes, pass
-through connector must be modified.
NOTE: Floor protector must be under horizontal pipe exit (See Figure 13. Page 19).
CEILING
CENTER LINE
OF ELBOW
SECURE WITH (3)
SHEET METAL SCREWS
FLOOR PROTECTOR
See Figure 13. Page 17.
ceiling as noted in (Figure 12). This will give you center
tee-box and chimney as per chimney
NFPA-211 Code and local building codes and is
1/4" RISE PER FT'
MARK PLUM LINE
SEAL AROUND PIPE TO
THIMBLE OR PASS-
THROUGH CONNECTOR
WITH NON-COMBUSTIBLE
MATERIAL
Figure 12
Page 16
WALL
MASONRY
FLUE
LINERS
CLEAN OUT
DOOR
MASONRY CHIMNEY