THIS HEATER CREATES WARM AIR CURRENTS. THESE CURRENTS MOVE HEAT
TO WALL SURFACES NEXT TO HEATER. DO NOT INSTALL HEATER WHERE
IMPURITIES IN THE AIR MAY EXIST.
NOTE: FOR GARAGE INSTALLATION
Heater pilot and burner must be at least 18" off the floor.
Locate heater AWAY FROM ANY MOVING VEHICLE.
Keep appliance area clear and free from combustible materials, gasoline and other
flammable vapors and liquids.
For convenience and efficiency, install heater:
in easy access locations
in coolest part of room
near an electrical outlet
Minimum Clearances are as follows:
42" from the top of the appliance to the ceiling. 5" from the right front corner of the appliance to an
adjacent side wall, and 5" from the left side of the appliance to an adjacent side wall. 7" from the
bottom of the appliance to the top surface of carpeting, tile or other combustible materials in the area
described. See figure 2 below.
• The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Note: Front Corner of heater
to an adjacent sidewall with
or without CSA listed
optional wooden mantel.
Figure 2
CAUTION
MINIMUM CLEARANCES TO
COMBUSTIBLE CONSTRUCTION
42"
5"
Left
Right
Side
Side
"Warning: This unit is not for Freestanding installation
with out Pedestal or Wooden Mantel."
See Installation/Instruction Manual for further details.
CAUTION:
air openings around appliance.
Improper operation will occur.
7"
For Wall Mount Unit
8
Do Not obstruct