Dacor Distinctive DTHP30 Installation Instructions Manual
Dacor Distinctive DTHP30 Installation Instructions Manual

Dacor Distinctive DTHP30 Installation Instructions Manual

Wall mount range hoods

Advertisement

Quick Links

Part No. 109174 Rev. A
Distinctive
Wall Mount Range Hoods
®
DTHP30, DTHP36, DTHP48
APPROVED FOR USE WITH ALL DACOR
TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507
STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 NO. 115 STANDARD
FOR FANS AND VENTILATORS.

Installation Instructions

®
RANGES AND COOKTOPS.

Advertisement

Table of Contents
loading

Summary of Contents for Dacor Distinctive DTHP30

  • Page 1: Installation Instructions

    Wall Mount Range Hoods ® DTHP30, DTHP36, DTHP48 ® APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS. TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507 STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 NO. 115 STANDARD FOR FANS AND VENTILATORS.
  • Page 2: Table Of Contents

    Remove the filters to view it. All specifications subject to change without notice. Dacor assumes no liability for changes to specifications. © 2008 Dacor, all rights reserved.
  • Page 3: Important Safety Instructions

    WARNING ating this or any other appliance. Hazards or unsafe practices that COULD result in severe • Always contact the Dacor Customer Service Team personal injury or death. about problems and conditions that you don’t under- stand. CAUTION Hazards or unsafe practices that MIGHT result in minor personal injury or property damage.
  • Page 4: General Safety Precautions

    The user should not install, repair, or replace any part of the range hood unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service. Contact the nearest Dacor authorized service representative at (800) 793-0093, or at www.dacor.com for examination, repair or adjustment.
  • Page 5: Product Specifications

    Product Specifications General Specifications Individual Models All Models Features Description Model Weight Fan Speeds Adjustable DTHP3010 51 lbs. (23 kg) Filters Mesh style, dishwasher safe DTHP3018 Exhaust(s) 8-inch duct diameter 53 lbs. (24 kg) DTHP3610 Total 120V, 60 Hz, 9 Amp. Max. DTHP3618 57 lbs.
  • Page 6: Dimensions

    Product Specifications Dimensions Electrical and Ductwork Connections Tolerances: +1/16” -0”, unless otherwise stated. Connect electrical wires and ductwork through the top or rear of the hood. Top Connections: All Models Single Exhaust Models** Dual Exhaust Models* Standard 8-inch duct Standard 8-inch duct Back of hood Electrical access holes...
  • Page 7 Product Specifications Dimensions Tolerances: +1/16” -0” unless otherwise stated. Dual Fan: Model DTHP48 Series Single Fan: DTHP30 & DTHP36 Series Hood Dimensions Model DTHP3010 29 7/8” (75.9 cm) 24” 10” 11 7/8” DTHP3610 35 7/8” (91.1 cm) (61 cm) (25.4 cm) (30.2 cm) DTHP4810 47 7/8”...
  • Page 8: Preparation And Setup

    Mesh filter Holding brackets and hardware (2) Halogen light bulbs Light replacement tool (1) Literature (2) Dacor Cleaning Creme (1) Necessary Tools and Hardware Please make sure these tools and hardware are within reach before beginning the installation. Hood Installation...
  • Page 9: Meeting Electrical Codes

    Preparation and Setup Installing the Electrical Source Meeting Electrical Codes WARNING Make sure electrical service to the range hood is installed by a licensed electrician. Install an electrical junction box near the hood’s electrical It is the owner’s responsibility to confirm that all electrical access holes according to local codes.
  • Page 10: Meeting Installation Requirements

    Preparation and Setup Meeting Installation Requirements WARNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Use only ductwork deemed acceptable by state, municipal and local codes. Electrical access WARNING rear To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the range should be avoided.
  • Page 11: Planning The Ductwork

    Wall Cap with • Two 8-inch exhausts may be merged into one 10-inch Roof Cap Damper duct using Dacor transition kit AHT10. See page 18 for details. * The equivalent lengths of roof and wall caps vary with model and configuration.
  • Page 12 Preparation and Setup Ductwork Tips Wherever possible, reduce the number of transitions, turns, • The hood exhaust connects to an 8-inch round duct. and sharp angles. Two staggered 45° angles are better You can increase the duct size over the duct run if than one sharp 90°...
  • Page 13: Preparing The Mounting Location

    Preparation and Setup Preparing the Mounting Location WARNING • The electricity to the range hood should be installed Holding brackets and hardware are provided to temporarily only by a licensed electrician. hold the hood in place while you permanently fasten the hood to the wall.
  • Page 14: Installation Instructions

    Installation Instructions Marking the Centerlines Top Exhaust These measurements and marks are for centering and leveling the hood, marking the duct cutouts, and installing the holding brackets. The holding brackets temporarily hold the hood while you mount it permanently into place. Have a marking tool, tape measure, and level ready.
  • Page 15: Installing The Holding Brackets

    Installation Instructions Installing the Holding Brackets Holding Bracket Cenerline Distance Models IMPORTANT: Placing the holding brackets above, below, or DTHP3010, DTHP3018 10 1/2 in (31.75 cm) off the centerline will cause alignment problems during final installation. DTHP3610, DTHP3618 7 1/8 in (18.1 cm) 1.
  • Page 16: Rotating The Fan(S) For Rear Exhaust

    Installation Instructions Rotating the Fan(s) for Rear Exhaust WARNING • Do not install the range hood unless the electrical service provided meets the range hood specifications. • Observe all governing codes and ordinances during installation. Contact your local building department for further information.
  • Page 17 Installation Instructions Rotating the Fans(s) for Rear Exhaust Various models illustrate these instructions, so the images Step 1 presented might not be an exact replication of the hood being installed. However, the best illustrations were chosen to help communicate the intended information. Instructions: Back of Hood Disassembling Parts...
  • Page 18 Installation Instructions Rotating the Fans(s) for Rear Exhaust Orientating the Blower/Vent L-Brackets Step 9 9. Unscrew and remove the L-bracket that is in the default top-venting orientation. 10. Turn and align the L-bracket so the hole is in back of Top of the hood, allowing a rear-venting configuration.
  • Page 19 Installation Instructions Rotating the Fan(s) for Rear Exhaust Orientating the Blower(s) Steps 11-13 It is imperative that the fan(s) are installed in the correct orientation. Detail: Location of Cable I/O Port To do this, make sure the cable I/O port is against the back of the hood.
  • Page 20: Using The Dual To Single Transition Kit# Aht10

    On dual exhaust models, the two 8-inch duct exhausts can be transitioned into one 10-inch duct. Assemble the Dacor transition kit # AHT10 before hanging the hood. This transition kit fits over the top or rear ventila- Bending the Flange for: tion exits.
  • Page 21 Installation Instructions Installing the AHT10 Top Vent: 3010, 3610, 4810 3018, 3618, 4818 Top Vent: 3010, 3610, 4810 3018, 3618, 4818 Dual vent model is shown 1. Center the AHT10 transition kit over the duct collars. 2. Drill holes for screws in the flanges. Make sure the holes pierce the top of the hood (see right).
  • Page 22: Hanging The Range Hood

    Installation Instructions Hanging the Range Hood WARNING Hanging the range hood requires two people. Do not attempt to lift the hood without assistance. When hanging the hood, be careful not to scratch or dam- age the hood. 1. Remove the plastic film from the hood. There are hanging slots in the back of the hood a few Holding brackets inches from the top.
  • Page 23: Hardwiring The Hood

    Installation Instructions Hardwiring the Hood WARNING • To avoid electric shock or fire hazard, make sure that power to the hood power supply line is turned OFF at the fuse box or circuit breaker before connecting the electrical wiring. • Miswiring the hood electrical wiring can create an electric shock or fire hazard and could damage the hood’s electrical system.
  • Page 24 Installation Instructions WARNING • Do not ground the circuit to a gas line. • Do not ground the circuit to a hot water pipe. • Water lines that are insulated must be jumped to assure continuity to ground. See below. To house circuit breaker Separate No.
  • Page 25: Verifying The Setup

    4. Repeat the above steps. FRONT • If the hood still does not work, contact Dacor Distinctive Service at (800) 793-0093 ex. 2822. • Do not attempt to repair the appliance yourself. Location of Filter Clips •...
  • Page 26: The Installation Checklist

    • Proper installation is the responsibility of the home- owner. The importance of proper installation of your Dacor range hood cannot be overemphasized. □ Is the hood properly attached to the wall according to the instructions on pages 13 and 20? □...
  • Page 27: Wiring Diagrams

    Wiring Diagrams DTHP3010, DTHP3018 WIRING DIAGRAM CONNECT TO HOOD HOOD 120V 60Hz 15A DTHP3010, 3018 LIGHT 75W LIGHT 75W POWER SUPPLY LIGHT LAMP LIGHT DIMMER CONNECTION TO ARLC/ARSC /ARSLC SWITCH FAN MOTOR CONNECTION TO REMOTE BLOWER ILHSF -8/10 OR REMP -3/16 CAUTION: DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
  • Page 28 Wiring Diagrams DTHP3610, DTHP3618 WIRING DIAGRAM CONNECT TO HOOD HOOD HOOD 120V 60Hz 15A LIGHT LIGHT LIGHT DTHP3610, DTHP3618 POWER SUPPLY LIGHT LAMP LIGHT DIMMER CONNECTION TO ARLC/ARSC /ARSLC SWITCH FAN MOTOR CONNECTION TO REMOTE BLOWER ILHSF -8/10 OR REMP -3/16 CAUTION: DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
  • Page 29 Wiring Diagrams DTHP4810, DTHP4818 WIRING DIAGRAM CONNECT TO HOOD HOOD HOOD HOOD 120V 60Hz 15A LIGHT LIGHT LIGHT LIGHT DTHP4810, DTHP4818 POWER SUPPLY LIGHT LAMP LIGHT DIMMER CONNECTION TO ARLC/ARSC /ARSLC SWITCH FAN MOTOR FAN MOTOR CONNECTION TO REMOTE BLOWER ILHSF -8/10 OR REMP -3/16 CAUTION: DISCONNECT POWER SUPPLY AT THE...
  • Page 30 Notes...
  • Page 32 Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com...

Table of Contents