Power Supply - Philips 160VW9FB/78 Service Manual

Hide thumbs Also See for 160VW9FB/78:
Table of Contents

Advertisement

60 60
HUDSON 9
IBM Modes
DOS
720x400@70Hz
DOS
640x400@70Hz
XGA
1024x768@72Hz
MAC Modes
VGA
640x480@67Hz
SVGA
832x624@75Hz
1024x768@60Hz
XGA
1024x768@75Hz
2.5 Factory Pre-set Modes for Analog Input
Starting the "RESET" function in the OSD-MENU will clear all old settings of auto configuration in preset modes
& OSD back to center
2.5.1
Protection Circuit
Missing or improper sync pulses will not damage the monitor. Additionally, under these conditions, the
monitor shall not cause damage to the driving source.

2.6 Power Supply

The power supply should be integrated to the monitor housing.
2.6.1
Features
A/C Line voltage range
A/C Line frequency range
Current
Peak surge current
Leakage current
Power line surge
2.6.2
Power Consumption
The monitor is equipped with a power-management according to NUTEK (power consumption) and is EPA
4.0 (Tier 2) compliant. There is a delay of 5s---7s before the transition from On-state to any power saving
state to avoid unintentionally entering of a power saving stage during display resolution and timing mode
changes. Transition from any power saving state to another can be instantaneous. The recovery from
Off-state requires no manual power on.
Mode
H-Sync.
Power-On
on
Power-saving
off
Switch off
off
Sync. On means:
Sync. Off means:
900 x 449
800 x 449
1304 x 798
864x525
1152x667
1312x813
1328x804
100 V ~ 240 V
50 ± 3Hz, 60 ± 3Hz
1.5A max. at 100V, 0.8A max. at 240V
< 55A peak at 240 VAC and cold starting
< 3.5Ma
No advance effects (no loss of information or defect) with a
maximum of 1 half-wave missing per second
V-Sync.
Video
on
active
off
blanked
off
off
Normal operation
H sync. F < 10KHz duty cycle > 25%
V sync. F < 10Hz
Horizontal
31.469
N
31.469
N
57.515
P
35.000
N
49.725
N
48.780
N
60.241
N
Pw-cons.
≦32W (with speaker)
≦28W (with out speaker)
2 W
1W
duty cycle > 25%
Vertical
70.087
P
28.322
70.087
P
25.175
72.1
P
75.000
66.667
N
30.240
74.551
N
57.2832
60.001
N
64.000
74.927
N
80.000
Indicator
Rec. time*
Green LED
--
Orange LED
< 10s
LED off

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

160vw

Table of Contents