Maintenance - Hitachi E10U Safety Instructions And Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
English
TROUBLESHOOTING
Lots of failures are caused by insufficient inspection or unfamiliar handling. Upon failure, inspect in the following
procedure. If any fault persists, contact the authorized HITACHI Service Center.
●The engine fails to star
Cause
● There is no fuel.
● The fuel pipe is clogged.
● The fuel strainer is clogged.
● The carburetor is clogged.
● The spark plug is dirty.
● The electrode gap of the spark plug
is incorrect.
● The engine oil is insufficient.
●Inspection of other parts
Cause
● The AC or DC protector is turned
off.
● The total power consumption of
the connected electric appliances
exceeds the operating range of the
generator.
● There is poor contact between the
plug and outlet.

MAINTENANCE

IMPORTANCE OF MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air
pollution.
WARNING: Improper maintenance or failure to correct a problem before operation can cause
malfunction, serious injury, or death. Always follow the inspection and maintenance
recommendation and schedules in this user's manual.
The following pages include a maintenance schedule, routine inspection procedures, and
simple maintenance procedures using basic hand tools, to help you properly care for your
generator. If you are not comfortable with any maintenance procedure, have the generator
serviced by a professional technician.
Maintenance, replacement, or repair of the emission control devices and system may be
performed by any engine repair establishment or individual, using parts that are "certified"
to EU standards.
MAINTENANCE SAFETY
WARNING: Always follow the procedures and precautions in the owner's manual. Failure to properly
follow maintenance instructions and precautions can lead to serious injury or death.
SAFETY PRECAUTIONS
CAUTION: Make sure that the engine is off before you begin any maintenance or repairs.
This will eliminate several potential hazards, including:
18
Remedy
● l Supply fuel.
● Clean the fuel pipe.
● Change the fuel strainer.
● Clean the carburetor.
● Clean the spark plug and dry it.
● Adjust the electrode gap to the
correct state.
● Supply engine oil.
Remedy
● Turn on the AC and DC protectors.
● Use only electric appliances so
that the power consumption is
contained in the operating range of
the generator.
● Securely insert the plug of the
electric appliance into the outlet.

Advertisement