NETGEAR ProSafe GSM7248R Hardware Installation Manual page 24

Managed layer 2 switches
Hide thumbs Also See for ProSafe GSM7248R:
Table of Contents

Advertisement

Managed Layer 2 Switches GSM7224R and GSM7248R Hardware Installation Guide
To connect a console to the switch:
1. Connect the null-modem cable to the console port on the rear of the switch.
Figure 2-4
2. Connect the other end of the cable to a workstation or terminal.
3. If you attached a workstation, start a terminal emulation program.
Microsoft Windows users can use HyperTerminal, which comes with the Windows
operating systems.
Macintosh users can use ZTerm.
UNIX users can use a terminal emulator such as TIP.
4. Configure the terminal-emulation program to use the following settings:
Baud rate: 9,600 bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
After you connect a console to the switch, you will need to configure the switch. The following
documents are provided for this purpose:
Quick Installation Guide. Explains basic setup and configuration (provided as both a print
document and in PDF format on the Resource CD).
Managed Layer 2 Switches 7200R Series CLI Reference Manual Version 7.0. Gives detailed
examples of how to use the CLI, and is located on the Resource CD.
NETGEAR 7000 Series Managed Switch Administration Guide Version 6.0. Describes
configuration examples, and is located on the Resource CD.
2-8
Console port
v1.0, November 2007
Hardware Installation