NETGEAR 2409 Installation Manual page 16

9 dbi omni-directional antenna
Table of Contents

Advertisement

Installation Guide for the 9 dBi Omni-directional Antenna ANT2409
Connect the grounding cable (not included) from the lightning arrestor to the ground of the
3.
building.
Grounding cable: The grounding cable must be equivalent or better than: AWG 10, UL 1015,
Stranded, 600 V, 105
cramped at both ends, cable no longer than 5 meters.
WARNING: the lightning arrestor and appropriate ground cable must be used for outdoor
installation. NETGEAR does not assume any responsibility in case of hazard resulting of
non-compliance with these instructions.
Screw the N/SMA Reverse Adapter on the lightning arrestor (clockwise) on the second RF
4.
port. Connect a NETGEAR cable model ACC-10314-01, 02, 03, 04 or 05 (sold separately) to
the adapter.
Locate the primary detachable antenna on the wireless access point. Remove the antenna and
5.
connect the other end of the NETGEAR cable ACC-10314-01, 02, 03, 04 or 05 to this port.
NOTE: On access points with two antennas, if you are only replacing one antenna, be sure to
replace the primary antenna and do not remove the secondary antenna.
After attaching your new 9 dBi antenna(s), reconnect your wireless device to the network and
6.
turn them on.
2-4
C, green or green/yellow insulation, 2 clip of 5.5 mm inner diameter
o
Installing the 9 dBi Omni-directional Antenna

Advertisement