GENERAL INSTALLATION GUIDELINES

Required Clearances

Figure 4: Outdoor Unit Clearances
24
12
28
Do not place the unit where animals and/or plants will be in the path of the warm air, or where the warm air and/or noise will disturb
neighbors.
Figure 6: Clearances Where There Are Obstacles on Both Air
Inlet and Outlet Sides (Obstacle on the Outlet Side is Lower
Than the Outdoor Unit)
Indoor Unit Clearance
Follow recommended best practices when choosing an indoor location for the Single
Zone Wall-Mounted indoor unit.
• Keep unit away from any indoor steam or excessive heat.
No obstacles should be placed around unit.
• Condensation drain (leakage piping) should be routed away from the unit.
Do not install near a doorway.
• Clearance gap between any wall or enclosure and the left or right side of the unit
must be greater than 4 inches.
• From the top of the unit to the ceiling there must be greater than 5 or 8 inches of
clearance (depending on indoor unit model).
• Unit should be at least 6.5 feet from the oor for adequate clearance.
Table 13: Indoor Unit Ceiling Clearance
"A" Ceiling Clearance (inches)
5
8
20
12
24
Unit: Inch
Unit: Inch
LSN181~240HSV3, LS307-360HV3, LSN240~360HLV, LSN90~240HEV, LSN180-240HEV1, LSN090-120HXV
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Figure 5: Outdoor Unit Sunroof/Awning Clearances
More than
12
F e n
c e o
o b s
r
t a c l
e s
Figure 7: Clearances Where There are Obstacles Above and on Both Air Inlet
and Outlet Sides (Obstacle on the Outlet Side is Lower Than the Outdoor Unit)
Figure 8: Single Zone Indoor Unit Clearance
Requirements
More than 4 inches
Indoor Unit Model(s)
LSN090-120HEV1, LSN091~121HSV3
More than
More than
24
More than
Unit: Inch
28
24
Minimum 28
Unit: Inch
Minimum clearance
from ceiling - "A"
At least 6.5 feet from the floor
12
More than
4 inches