Download Print this page

LG LS120HEV Submittal Data

Mega single zone inverter
Hide thumbs Also See for LS120HEV:

Advertisement

Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
LS120HEV
Mega Single Zone Inverter
Outdoor Unit (ODU) ‐ LSU120HEV
Performance:
Cooling:
Capacity (Btu/h)
SEER
EER
SEER ‐ Seasonal Energy Efficiency Ratio EER ‐ Energy Efficiency Ratio
Heating:
Capacity (Btu/h)
HSPF
HSPF ‐ Heating Seasonal Performance Factor
Cooling Nominal Test Conditions:
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Electrical:
Outdoor Unit:
Power Supply (V¹/Hz/Ø)
MOP (A)
MCA (A)
Cooling Rated Amps (A)
Heating Rated Amps (A)
Compressor (A)
Fan Motor (A)
MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity
Indoor Unit:
Power Supply (V¹/Hz/Ø)
Cooling Power Input (kW)
Heating Power Input (kW)
Piping:
Liquid Line (in, OD)
Vapor Line (in, OD)
Additional Refrigerant (oz/ft)
Max Pipe Length (ft)²
Piping Length (no add'l refrigerant, ft)
Max Elevation (ft)
Controls Features:
•24‐Hour on/off  mer
•Energy saving
•2‐Way (up/down) auto 
•Inverter (variable speed 
swing
compressor)
•Auto changeover
•Jet cool
•Auto restart
•Self‐cleaning indoor coil
•Condensate sensor 
•Sleep mode
connection
•Ultra quiet opera on
For continual product development, LG reserves the right to change specifications without notice.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com.
For:
GC:
Mech:
(Project Manager)
Indoor Unit (IDU) ‐ LSN120HEV
12,000
16.3
10.26
12,000
8.5
Heating Nominal Test Conditions:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
208‐230/60/1
7.3
7.3
6.8
0.5
208‐230/60/1
1.17
0.98
1/4
3/8
0.22
File
Resubmit
Approval
Other
Operating Range:
Outdoor Unit:
Cooling (°F DB)
Heating (°F DB)
Indoor Unit:
Cooling (°F DB)
Heating (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control
Refrigerant Charge (lbs)
ODU Sound Pressure (±3 dB(A))³
IDU Sound Pressure ±3 (H/M/L) dB(A)³
ODU Net Unit Weight (lbs)
15
ODU Shipping Weight (lbs)
9
IDU Net Unit Weight (lbs)
IDU Shipping Weight (lbs)
Heat Exchanger Coating
Fan:
ODU Type
IDU Type
Fan Speeds (Fan/Cooling/Heating)
Quantity (ODU + IDU)
Motor/Drive
ODU Max Air Flow Rate (CFM)
IDU Air Flow Rate H/M/L (CFM)
Dehumidification (pts/hr)
Notes:
1.Acceptable opera ng voltage: 187V‐253V.
2.Piping lengths are equivalent.
49
3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
4.All power/communica on cable to be minimum 18 AWG, 4‐conductor, stranded, 
25
shielded and must comply with applicable local and national code.
5.See Engineering Manual for sensible and latent capaci es.
23
6.Power wiring cable size must comply with the applicable local and na onal code.
7.The indoor unit comes with a dry helium charge.
8.This data is rated 0   above sea level, with 24.6   of refrigerant line and a 0   level 
difference between outdoor and indoor units.  
9.Must follow installa on instruc ons in the applicable LG installa on manual.
Tag #:
Brushless Digitally Controlled/Direct
DFS‐SB‐AL‐002‐US 013C20
64‐118
23‐75
64‐86
690‐86
R410A
Capillary Tube
1.65
47
39/33/25
49
53
20
25
GoldFin™
Propeller
Cross Flow
3/4/3
1 + 1
956
353/272/212
2.75
Page 1 of 2

Advertisement

loading

Summary of Contents for LG LS120HEV

  • Page 1 Max Pipe Length (ft)² 3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 4.All power/communica on cable to be minimum 18 AWG, 4‐conductor, stranded,  Piping Length (no add'l refrigerant, ft) shielded and must comply with applicable local and national code. 5.See Engineering Manual for sensible and latent capaci es. Max Elevation (ft) 6.Power wiring cable size must comply with the applicable local and na onal code. 7.The indoor unit comes with a dry helium charge. Controls Features: 8.This data is rated 0   above sea level, with 24.6   of refrigerant line and a 0   level  difference between outdoor and indoor units.   •24‐Hour on/off  mer •Energy saving 9.Must follow installa on instruc ons in the applicable LG installa on manual. •2‐Way (up/down) auto  •Inverter (variable speed  swing compressor) •Auto changeover •Jet cool •Auto restart •Self‐cleaning indoor coil •Condensate sensor  •Sleep mode connection •Ultra quiet opera on For continual product development, LG reserves the right to change specifications without notice. DFS‐SB‐AL‐002‐US 013C20 Page 1 of 2...
  • Page 2 Job Name/Location: Outdoor Unit (ODU) ‐ LSU120HEV Tag #: Date: Mega Single Zone Inverter PO No.: For continual product development, LG reserves the right to change specifications without notice. ©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com. DFS‐SB‐AL‐002‐US 013C20 Page 2 of 2...
  • Page 3 Job Name/Location: Tag #: Indoor Unit (IDU) ‐ LSN120HEV Date: Mega Single Zone Inverter PO No.: For continual product development, LG reserves the right to change specifications without notice. ©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com. DFS‐SB‐AL‐002‐US 013C20 Page 3 of 3...