8

Applicable controls

REQUIREMENT
When the air conditioner is used for the first time, it will
take some moments after the power has been turned on
before the remote control becomes available for
operations: This is normal and is not indicative of trouble.
• Concerning the automatic addresses (The automatic
addresses are set up by performing operations on the
outdoor interface circuit board.)
While the automatic addresses are being set up, no
remote control operations can be performed. Setup
takes up to 10 minutes (usually about 5 minutes).
• When the power is turned on after automatic address
setup
It takes up to 10 minutes (usually about 3 minutes) for
the outdoor unit to start operating after the power has
been turned on.
Before the air conditioner was shipped from the factory,
all units are set to [STANDARD] (factory default). If
necessary, change the indoor unit settings.
The settings are changed by operating the wired remote
control.
* The settings cannot be changed using only a wireless
remote control, simple remote control or group control
remote control by itself so install a wired remote
control separately as well.
23-EN
 Changing applicable control
setting
Basic procedure for changing settings
Change the settings while the air conditioner is not
working.
(Stop the air conditioner before making settings.)
1
3
4
6
1
5
2
1
Push
button and temp. setup
button
simultaneously for 4 seconds or more.
After a while, the display flashes as shown in the
figure.
Confirm that the CODE No. is [01].
• If the CODE No. is not [01], push
button to
erase the display content, and repeat the
procedure from the beginning.
(No operation of the remote control is accepted
for a while after
button is pushed.)
(While air conditioners are operated under the
group control, "
" is displayed first.
When
button is pushed, the indoor unit
number displayed following "ALL" is header
unit.)
(* Display content varies with the
indoor unit model.)
2
Each time
button is pushed, indoor
unit numbers in the control group change
cyclically. Select the indoor unit to change
settings for.
The fan of the selected unit runs and the louvers
start swinging. The indoor unit can be confirmed
for which to change settings.
3
Specify CODE No. [
] with temp. setup
/
buttons.
4
Select SET DATA [
] with timer time
/
buttons.
5
Push
button. When the display changes
from flashing to lit, the setup is completed.
• To change settings of another indoor unit,
2
repeat from Procedure
.
• To change other settings of the selected indoor
3
unit, repeat from Procedure
.
Use
button to clear the settings.
To make settings after
button was pushed,
2
repeat from Procedure
.
6
When settings have been completed, push
button to determine the settings.
When
button is pushed, "SETTING" flashes
and then the display content disappears and the
air conditioner enters the normal stop mode.
(While "SETTING" is flashing, no operation of the
remote control is accepted.)
 Installing indoor unit on high
ceiling
When an indoor unit is installed on a ceiling higher than
the standard height, make the high-ceiling setting for
fan speed adjustment.
Follow to the basic operation procedure
1
2
3
4
5
6
(
).
3
• For the CODE No. in Procedure
, specify [5d].
4
• Select the SET DATA for Procedure
"Height list of ceiling possible to be installed" table on
page 4 in this manual.
– 12 –
Remote control-less setting
To set the unit to high ceiling setting, there is a method
that requires the changing of the short plugs on the
indoor P.C. board. The details are shown in the below
table.
This method is only to be used where a wired remote
control (Group control) is not used.
* However, once the setting is changed, it is
necessary to reset the setting back to 0000 that
placing the short plugs back to the factory default
position and rewriting the setting data back to 0000
with wired remote control. (The setting can be
changed to 0001 and 0003 without resetting.)
• Select by exchange of short plugs on indoor P.C.
board.
Short plug position
SET
DATA
Short
Open
CN112 CN111 CN110
0000
Standard (Factory default)
CN112 CN111 CN110
0002
High ceiling (2)
CN112 CN111 CN110
0003
High ceiling (3)
• Short plugs position (CN112, CN111, CN110 from
the left)
from the
Note
EN
24-EN

Advertisement

Table of Contents
loading

Table of Contents