Comb Filter Phase Adjustment; Comb Filter Level Adjustment - Sanyo VM-EX220P Adjustment Manual

8 mm
Table of Contents

Advertisement

4. Comb
Filter
Phase
Adjustment
[Connection]
J1OO5
VRI1l
[Adjustment
/ Check]
pleasuring Point
Measuring Equipment
Condition
TP101 (CH1)
Oscilloscope
stop
TP105 (EXT)
TP143 (GND)
Input Signal / Alignment Tape
Color bar
ADJ. Location
ADJ. / Check Value
VR111
Preparation:
POWER switch: "PLAYER"
" Short pin @, pin @ and pin @ of J1OO5.
Adjusting
/ Checking
method:
1. Adjust with VR111 so that the amplitude (residual chroma
level) of green becomes minimum
n
h
Residual chroma level
-
minimum
5.
Comb Filter Level Adjustment
[Connection]
J1OO5
VR102
o
TP105
TP143 O
m
n
.
~Q
CH1
EXT
OCH2
u
u
[Adjustment
/ Check]
Measuring Point
Measuring Equipment
Condition
TP101 (CH1)
Oscilloscope
stop
TP105 (EXT)
TP143 (GND)
Input Signal / Alignment Tape
Color bar
I
ADJ. Location
ADJ. I Check Value
VR102
Preparation:
POWER switch: "PI A YER"
Short pin @, pin @ and pin @ of J1OO5.
Adjusting / Checking method:
1. Adiust with VR102 so that the amplitude
(residual chroma
level) of greeen becomes minimum (below 25 mVp-p).
n
4
Residual chroma level
~ minimum
,.i
\
+
– 5-16 –