5,100K Awb Adjustment; 2,800K Awb Adjustment - Sanyo VM-EX220P Adjustment Manual

8 mm
Table of Contents

Advertisement

11.5,1 00K AWB Adjustment
r~mnnactinnl
---
. . . ..... . ... ...
L
L
I
R
00
D1
12. 2,800K
AWB Adjustment
[Connection]
-––
TP141
F% %
VR931
VR932
m
o
—.-
—..
—..
—..
—..
[Adjustment]
[Adjustment]
Meaauring Point
Measuring Equipment
Condition
TP141 [CP1]
Vectorscope
CAMERA EE
(video output)
Color viewer 5,1 00K
TP143 (GNDj
Subject
All white pattern
ADJ. Location
ADJ. Value
EVRCH1l,
CH12
Preparation:
Short pin @ and pin @ of J9001.
Adjusting
method:
1. Set the gain so that the burst comes to the end of the
vectorscope.
2. Press the RESET key once (when using VJ8-01 03).
Press the RESET key and AID key simultaneously,
and
then release the RESET key first (when using VJ8-0141 ).
3. Press the READ key once while pressing the AID key and
read out all the EVR data.
4. Adjust two EVRS of CH11 and CH12 mutually so that the
white vector displayed
luminance
point is positioned
on
the point as shown in the figure. (See page 5-1 O)
5. Press
the
WRT key once while pressing the AID key to
store the adjusting data.
Measuring Point
Measuring Equipment
Condition
TP141 [CP1]
Vectorscope
CAMERA EE
(video output)
Color viewer 5,1 00K
TP143 (GND)
Subject
All white pattern
(Place two LBA8s in front of the lens)
ADJ. Location
ADJ. Value
VR931 (R. G)
VR932 (B. G)
Preparation:
Short pin @,
pin @ and pin @ of J9001.
Adjusting
method:
1. Set the gain so that the burst comes to the end of the
vectorscope.
2. Adjust with the VR931 (R. G) and VR932 (B. G) so that
the white vector displayed
luminance
point is positioned
on the point as shown in the figure. (See page 5-1 O)
EVR CH7
R – YGAIN
EVR CH8
B–YGAIN
EVR CH9
R - Y MATRIX
EVR CH1 O
B – Y MATRIX
EVR CHI 1
R CONTROL
EVRCH12
B CONTROL
– 5-9 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vm-ex370pVm-ex280p

Table of Contents