Toshiba RAS-24N3KV2-A Service Manual page 83

Table of Contents

Advertisement

Block distinction
Check
Block
code
Operation of diagnosis function
Check
Cause of operation
code
Return signal of the outdoor
unit has been sent when
operation start. But after
that, signal is stop some time.
Instantaneous power
failure.
Some protector
(hardware) of the
outdoor unit open
circuit of signal.
Signal circuit of indoor
P.C. board or outdoor
P.C. board is failure
in some period.
Air
Display
conditioner
flashing error
status
Indoor unit
Flashes when
operates
error is detected. 2. If the air conditioner repeat operates
continue.
Flashing stop
Outdoor unit
and outdoor unit
stop.
start to operate
when the return
signal from the
outdoor unit is
normal.
– 82 –
FILE NO. SVM-13004
Action and Judgment
1. Check power supply (Rate + 10%)
and stop with interval of approx. 10
to 40 minutes.
Check protector (hardware) such
as Hi-Pressure switch,
Thermal-Relay, etc.
Check refrigerant amount, packed
valve opening and any possibility
cause which may affect high
temperature or high pressure.
3. Check operation signal of the indoor
unit by using diode. Measure voltage
at terminal block of the indoor unit
between No.2 and No.3 (or L2 and S)
If signal is varied 15-60V continuously,
replace inverter P.C. board.
If signal is not varied, replace indoor
P.C. board.