Item
Note:
Gas train
Table 34: Remedy the cause, re-enable starting
46 | Operation | MS150108/00E 2013-06
Action
A contact is provided to request the ventilation system in the scaveng-
•
ing phase.
•
The gas control system must be equipped with an SAV (safety shut-off
valve) when using gas control systems with inlet pressures in excess
of 0.1 bar. If the SAV is tripped by an EMERGENCY STOP it must be
reset manually. SAV tripping is not indicated by the engine.