Software Version - Sharp LC-80LE642U Service Manual

Hide thumbs Also See for LC-80LE642U:
Table of Contents

Advertisement

LC-80LE642U
11. Factory setting
For finish the Initialize process, needed to pull out AC cord, After Factory Initialize.
CAUTION: After Factory Initialize, Do not turn on again. When you turn on TV, please do Factory Initialize again.
Adjustment point
Adjustment conditions
1
Factory setting
Need to pull out AC cord for
process complete.

12. Software version

1. Main microprocessor
OKLA_LE857_xxx.USB
OKLA_LE857_xxx.DAT
OKLA_LE857_xxx_CHK.USB
OKLA_LE857_xxxxxxxx.PCC
2. Monitor microprocessor
OKLAMxxx.SMB
3. T-CON ROM
CLOVERxxxxxxxxxxxxxxxxxxxxxxx.ROM
13. Writing the inch and model name onto EEPROM
1. Enter the adjustment process mode.
2. Point the cursor to [MODEL NAME] (Page 29/29).
3. Select "LE642U", and press [Enter] key.
4. "OK" is displayed.
5. Point the cursor to [PANEL SIZE] (Page 29/29).
6. Select "80" and press [Enter] key.
7. Moments later image is displayed.
8. Turn off power
9. Turn on power
Select [INDUSTRY INIT(+Cause)], Set to [ON] by [+], [-] of [VOL] Button [+], [-], then
press [ENT] key.
Display change to green and show the version.
Process complete at display show [SUCCESS].
(At error, picture become to RED with [ERROR] OSD)
Turn off the AC power.
Below items initialize by Factory Initialize.
1) User set value
2) Channel data
3) Password
4) Operating time
5) Standby Cause
6) Auto installation flag
7) V-CHIP block setting
5 – 14
Adjustment procedure

Advertisement

Table of Contents
loading

Table of Contents