Philips 17S1AB Service Manual page 4

17inch tft wxga lcd colour monitor
Table of Contents

Advertisement

17S1 LCD
4
AUO panel
Type NR.
: AUO M170ETN01.0
Resolution
: 1280x1024 (SXGA)
Outside dimensions
: 358.5(H) x 296.5(V) Typ. x 15.8(D) Max.
Pitch (mm)
: 0.264mm x 0.264mm
: 1280 horiz. By 1024 vert. Pixels RGB strip
Color pixel arrangement
arrangement
Display surface
: Anti-glare type, Hardness 3H
Color depth
: 16.7M colors (RGB 6-bits+Hi-RFC data)
Backlight
: 2 CCFL
Active area (W x H)
: 337.920(H) × 270.336(V) mm
View angle (CR=10)
: =170 for Right/Left (Typ)
: =160 for Up/Down (Typ)
Contrast ratio
: 1000:1 (Typ)
White luminance
: 250 (center,Typ)@CCFL=7.5 mA
Color gamut
: >=72%
Gate IC
: NEC uPD160947 , Raydium RM7601
Source IC
: NEC uPD160995 , Raydium RM7103
Response time
: <=5 ms (Typ)
Vertical frequency range : 49~76Hz
Scanning frequencies
Hor.
: 30 – 83 K Hz
Ver.
: 56 - 76 Hz
: < 140 MHz for VGA and < 140 MHz for
Video dot rate
DVI, warning message must be
displayed while over 140 MHz (supplier to provide accurate scaler
bandwidth number)
Power input
: 90-264 V AC, 50/60 ± 2 Hz
Power consumption
: <24 W maximum
Functions:
(1) D-SUB analog R/G/B separate inputs, H/V sync separated,
Composite (H+V) TTL level, SOG sync
(2) DVI digital Panel Link TMDS inputs, HDCP supported.
Ambient temperature:
Power input connection
Power cord length : 1.5M
Power cord type
: 3 leads power cord with protective earth plug.
Power management
The monitor must comply with the Microsoft On Now
specification, and meet EPA requirements.
Mode
HSYNC VSYNC
Power-On
On
On
Standby
Off
Off
DC Power
Off
0 °C - 40 °C
Video
Pwr-cons.
Indication
active
< 24W(max) WHITE LED
WHITE
LED flashing
blanked
< 0.8 W
3 sec on/3
sec off
N/A
< 0.5 W
LED Off
Technical Data
PIN No. SIGNAL
1
Red
2
Green/ SOG
3
Blue
4
Sense (GND)
5
Cable Detect (GND)
6
Red GND
7
Green GND
8
Blue GND
Susceptibility of display to external environment
Rec.
Operating
time
--
< 3 s
Storage
Note: recommend at 5 to 35° C, Humidity less than 60 %
PIN No. SIGNAL
9
DDC +3.3V or +5V
10
Logic GND
11
Sense (GND)
12
Bi-directional data
13
H/H+V sync
14
V-sync
15
Data clock
Pin No.
Description
1
T.M.D.S. data2-
2
T.M.D.S. data2+
3
T.M.D.S. data2 shield
4
No Connect
5
No Connect
6
DDC clock
7
DDC data
8
No Connect
9
T.M.D.S. data1-
10
T.M.D.S. data1+
11
T.M.D.S. data1 shield
12
No Connect
13
No Connect
14
+5V Power
15
Ground (for +5V)
16
Hot plug detect
17
T.M.D.S. data0-
18
T.M.D.S. data0+
19
T.M.D.S. data0 shield
20
No Connect
21
No Connect
22
T.M.D.S clock shield
23
T.M.D.S. clock+
24
T.M.D.S. clock-
- Temperature : 0 to 35 degree C
- Humidity
: 80% max
- Altitude
: 0-3658m
- Air pressure
: 600-1100 mBAR
- Temperature
: -20 to 60 degree C
- Humidity
: 95% max
- Altitude
: 0-12192m
- Air pressure
: 300-1100 mBAR

Advertisement

Table of Contents