Sony HCD-U1BT Service Manual page 2

Cd
Hide thumbs Also See for HCD-U1BT:
Table of Contents

Advertisement

HCD-U1BT
Ver. 1.3
QQ
3 7 63 1515 0
Tuner section
FM stereo, FM/AM superheterodyne tuner
FM tuner section:
Tuning range
Pan-American models:
87.5 – 108.0 MHz (100 kHz step)
Other models:
87.5 – 108.0 MHz (50 kHz step)
Antenna: FM lead antenna
Antenna terminals: 75 ohms unbalanced
Intermediate frequency: 10.7 MHz
AM tuner section:
Tuning range
Pan-American models:
530 – 1,710 kHz (with the tuning interval
set at 10 kHz)
531 – 1,710 kHz (with the tuning interval
set at 9 kHz)
European model:
531 – 1,602 kHz (with the tuning interval
set at 9 kHz)
Korean model:
530 – 1,710 kHz (with the tuning interval
set at 10 kHz)
531 – 1,602 kHz (with the tuning interval
set at 9 kHz)
Antenna: AM loop antenna, external antenna
terminal
Intermediate frequency: 450 kHz
General
Power requirements
TE
North American model:
L 13942296513
120 V AC, 60 Hz
European model:
220 – 240 V AC, 50/60 Hz
Korean model:
220 – 240 V AC, 60 Hz
Power consumption: 35 watts
Dimensions (w/h/d) (excl. speakers):
Approx. 160 × 241 × 218 mm
Mass (excl. speakers) 3.2 kg
Design and specifications are subject to change
without notice.
www
.
2
http://www.xiaoyu163.com
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples
of a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2 V AC range are suitable. (See
Fig. A)
To Exposed Metal
Parts on Set
Q Q
3
6 7
1 3
1 5
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE
WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR
IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
co
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES
PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE
.
FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT
DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS
PUBLIÉS PAR SONY.
9 4
2 8
0 5
8
2 9
9 4
2 8
AC
1.5 k Ω
voltmeter
(0.75 V)
Earth Ground
m
9 9
9 9