FDTN-H
Model FDTN508HES
Item
Nominal cooling capacity
(1)
(1)
Nominal heating capacity
Power source
Cooling input
Running current (Cooling)
Power factor (Cooling)
Heating input
Running current (Heating)
Power factor (Heating)
Cooling input
Running current (Cooling)
Power factor (Cooling)
Inrush current (L.R.A)
(4)
Noise level
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
High pressure control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow (Standard)
Fresh air intake
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
Cooling
(2) This packaged air conditioner is manufactured and tested in conformity with the following standard. JIS B8616 "UNITARY AIR CONDITIONERS"
(3) The operation data indicate when the air conditioner is operated at 380/415V 50Hz and 380V 60Hz respectively.
(4) Indicates the value at mild mode.
200
Model
ISO-T1
W
ISO-T3
ISO-T1
W
kW
A
%
kW
A
%
kW
A
%
A
dB(A)
mm
kg
kW
Louver fins & inner grooved tubing
kg
r
W
CMM
Rubber sleeve (for fan motor)
W
Wireless remote control switch
Internal thermostat for fan motor.
mm
(in)
Item
Indoor air temperature
DB
27˚C
20˚C
29˚C
FDTN508HES
FDTN508H
12500/14000
11900
12800/14400
3 Phase, 380-415V 50Hz or 380V 50Hz/415V 50Hz, 380V 60Hz
4.87/4.87/5.83
10.0/10.0/11.0
74/68/81
4.49/4.51/5.41
9.2/9.3/10.2
74/67/81
6.43
12.0
81
68
Hi:49 Lo:43
Unit 320 × 840 × 840
Panel 30 × 950 × 950
36 (Unit:30 Panel:6)
Capillary tube
R22
Holding charged
IC controlled de-icer
High pressure regulator valve
Turbo fan × 1
130 × 1
Line starting
Hi:28 Lo:20
Available
Long life filter ×1(washable)
Thermostat by electronics
Frost protection thermostat.
Liquid line: φ9.52 (3/8") Gas line: φ19.05 (3/4")
Flare piping
(Connectable with VP25)
Necessary (both Liquid & Gas lines)
Mounting kit. Wireless remote controller. Drain hose
Decorative Panel
Outdoor air temperature
WB
DB
19˚C
35˚C
7˚C
19˚C
46˚C
FDC506HES3
59
1250 × 950 × 340
91
RC5563ESE2 × 1
3.73
Line starting
Slitted fins & bare tubing
Capillary tube
2.3 [Pre-charged up to the piping length of 5m]
2.07 (SUNISO 3GS)
Propeller fan × 2
60 × 2
Line starting
100/110
Rubber mount (for compressor)
40 (Crank case heater)
– (Indoor unit side)
Internal protector for compressor.
Internal thermostat for fan motor.
Internal pressure relief valve for compressor.
Standards
WB
24˚C
ISO-T1, JIS B8616
6˚C
24˚C
ISO-T3, SASO