Alignment Procedures; Electrical Specification; Electrical Characteristics; Adjust Point - Harman Kardon AVR-134 Service Manual

Hide thumbs Also See for AVR-134:
Table of Contents

Advertisement

1.Electrical specification.

NO.
1-1
Local OSC
1-2
Frequency cover range
1-3
Standard supply voltage
1-4
FM Antenna input Impedance
1-5
AM Loop Antenna

2.Electrical Characteristics.

NO
TEST ITEMS
AF Output Level
FM
Auto Stop Level
Stereo Separation
AF Output Level
MW
Auto Stop Level

3.Adjust Point.

<KST-MU004MV1-0 Adj POINT>

ALIGNMENT PROCEDURES

ITEMS
TEST
T.P.
CONDITION
47Ω Load
98.1
98.1
98.1
1kHz
47Ω Load
999
999
FM STEREO SEPARATION Adj.
SVR01
FM AUTO STOP LEVEL Adj.
SPECIFICATION
M W
Above the receiving Frequency
522 ~1620kHz
12.0(±0.5V)
75 ohm
9.5uH ( 1kHz ) : S0160BL-25
T.L.
MOD.
Specification
dBu
kHz,%
60
280±100
40
--
25 ±6
60
25 min
74
30
180 ±60
--
30
55 ±15
SVR02
21
F M
87.5 ~ 108.0MHz
UNIT
Adjustment
mV
Non Adjust
dBu
SVR01
dB
SVR02
mV
Non Adjust
dBu
Non Adjust

Hide quick links:

Advertisement

Table of Contents
loading