D.6
EA11 Decoded 2D Imager
Parameter
Scan Rate
Linear Emulation Mode
Scan Angle
Optical Resolution
Print Contrast
Versions
Symbologies - 1D
Symbologies - 2D
Voltage (optics)
Operating Current
Power Saving Mode
Ambient Light
Regulatory Approvals
D.6.1
EA11 Typical Reading Distances
Appendix D: Internal Imager & Scanner Specifications
2D mode: 56 images/s auto adaptive
200 scans/s auto adaptive
38.9° (horizontal), 25.4° (vertical)
752 (H) x 480 (V) pixels, 256 gray levels
down to 25%
Standard range
EAN/UPC, GS1 Databar (limited expanded & omni-directional), RSS, Code 39, Code 128,
UCC/EAN 128, ISBN, ISBT, Interleaved/Matrix/ Industrial and Standard 2 of 5, Codabar,
Code 93/93i, Code 11, MSI, Plessey, Telepen, postal codes (Australian Post, BPO,
Canada Post, Dutch Post, Japan Post, PostNet, Sweden Post)
Data Matrix, PDF417, Micro PDF 417, Codablock Maxicode, QR, Aztec GS1 composite
codes
3.3V -5% / +10% (typical values)
170mA - 310mA (lighting condition dependent)
2mA
Works in any lighting conditions, from 0 to 100,000 lux
UL, VDE certified, RoHS compliant
Psion Omnii Hand-Held Computer User Manual
EA11 Decoded 2D Imager
Specification
D-9