DUAL FUEL CONFIGURATION
6.
once to set Cd (Compressor delay).
Press
After the Auxiliary heat is turned on, the
compressor shutdown is delayed for the time
selected (default is 60 seconds).
7.
once to display Auxiliary
Touch
Off (AO). Using
or
set the temperature to 80
outdoor temperature is above the selected
temperature, the auxiliary heat will not turn on.
8.
once will enable the Blower
Pressing
Balance Point (bP). Toggle
set the bP to 80
, this feature de-energizes
o
the DHM terminal to operate the blower at
a slower speed for first stage heat when the
outdoor temperature is below the temperature
selected.
9.
Press
once to move to next menu item.
Dual Fuel (dF) is configured.
10.
Press the
touch key to exit the Installer
Configuration Menu.
6
Quick Set-Up Guide for Touchscreen Thermostats
touch keys
. As long as the
o
or
to
Dual Fuel (dF) OFF
1.
With remote sensor enabled and dF(OFF),
once will change to Auxiliary
pressing
Off (AO). As long as the outdoor temperature
is above the selected temperature, the
auxiliary heat will not turn on. Using
touch keys, set the temperature, default is 80
2.
once will enable the Blower
Pressing
Balance Point (bP). Toggle
the bP. This feature de-energizes the DHM
terminal to operate the blower at a slower
speed for first stage heat when the outdoor
temperature is below the temperature selected.
Default is 80
.
o
3.
Press
once to move to next menu item.
Dual Fuel (dF) is configured.
4.
Press the
touch key to exit the Installer
Configuration Menu.
or
.
o
or
to set