Installation location
Install the appliance in a dry, well venti
lated room. The installation location
should neither be exposed to direct
sunlight nor near a heat source, e.g. a
cooker, radiator, etc. If installation near
a heat source is unavoidable, use a
suitable insulating plate or observe the
following minimum distances to a heat
source:
- 3 cm to an electric cooker.
- 30 cm to an oil or solid fuel cooker.
The floor on which the appliance is to
be installed must be rigid. If required,
reinforce the floor.
The appliance is very heavy, for empty
weight see the following table.
Basic model
Model with dispenser
To ensure that the ice maker functions
correctly, the appliance must be up
right. Align the appliance with a spirit
level. To ensure that the doors can
open all the way, observe lateral mini
mum distances when installing the
appliance in a corner or recess (see
section on Appliance dimensions").
Connecting the
appliance
After setting up the appliance, wait for
at least one hour before starting the
appliance up. The oil contained in the
compressor may have been displaced
into the refrigeration system during
transport.
Clean the inside of the appliance before
it is first used (see Cleaning").
The appliance conforms to protection
class I. Connect the appliance to a
220 240 V / 50 Hz alternating current
supply using a socket with protective
earthing conductor which has been
correctly installed.
The socket must be near to the
appliance and easily accessible after
the appliance has been installed.
The socket must be protected by a fuse
with a rating of 10 A to 16 A.
28
In the case of appliances operated
outside of Europe, check whether the
voltage and type of current specified
conform to the values of your power
supply.
You will find this information on the
rating plate.
Warning
!
The appliance must never be
connected up to an electronic energy
saving socket.
Sinusoidal commutated and line
commutated inverters can be used with
our appliances.
Line commutated inverters are used
with photovoltaic systems that are
connected directly to the power supply.
Sinusoidal communicated inverters
must be used with standalone applica
tions (e.g. on ships or mountain huts)
that do not have a direct connection to
the power supply.
Caution:
104 kg
Fit strain relief when installing or repla
cing the power cord.
113 kg
Do not use extension cables or distri
butors.
Observe ambient
temperature and
ventilation
Ambient temperature
The atmosphere grade is written on the
identification plate. It states the room
temperature within which the appliance
can be operated.
Atmosphere grade
SN
N
ST
T
Note:
The appliance can function within the
ambient temperature limits of the
specified climate class. If an appliance
in the SN climate class is operated at
lower ambient temperatures, damage
to the appliance can be excluded up to
a temperature of +5 °C.
Ventilation
The heated air must be able to escape
unimpeded. Otherwise, the refrige
rating unit has to work harder, which
increases the appliance's power
consumption.
Therefore: You must never cover or
block the ventilation openings!
Switching on
the appliance
S Insert the mains plug into a socket.
The appliance begins to cool down as
soon as it is connected to the power
supply. When the doors are open, the
interior lights come on.
Note:
The preset temperatures (factory
settings) are reached after approx. 2 to
3 hours. Do not put any food in the
appliance beforehand.
To change the set temperatures > see

Setting the temperature".

Setting the
temperature
- The temperature for the refrigerator
To change the values:
S Keep pressing the Selection button
until the required temperature value is
indicated.
Permitted ambient
temperature
+10 ºC to 32 ºC
+16 ºC to 32 ºC
+16 ºC to 38 ºC
+16 ºC to 43 ºC
The value last indicated is saved by the
system.