Amana *MSS96 Series Technical Manual page 7

34.5" single stage multi-speed gas furnace up to 96% afue
Table of Contents

Advertisement

FURNACE SPECIFICATIONS
High Fire Input„
High Fire Output„
AFUE†
Temperature Rise Range ( F)
Vent Diameter‡
No. of Burners
Circulator Blower
Available AC @ 0.5" ESP
Size (D x W)
Horsepower @ 1075 RPM
Speed
Filter Size (in†)
Permanent
Disposable
Electrical Data
Min. Circuit Ampacity
Shipping Weight (lbs)
„ Natural Gas BTU/h
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
" FPT
and noise issues.
greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence
over clearances from the enclosure where accessibility clearances are greater.
*CSS96
*CSS96
0402BNA
0603BNA
40,000
60,000
38,400
57,600
96
96
25 - 55
35 - 65
2" - 3"
2" - 3"
2
3
1.5 - 3
1.5 - 3
10" x 8"
10" x 8"
4
4
427
512
213
256
9.6
9.6
15
15
N/A
N/A
*CSS96
*CSS96
0804CNA
1005CNA
80,000
100,000
76,800
95,000
96
95
35 - 65
40 - 70
2" - 3"
2" - 3"
4
5
2.5 - 4
3 - 5
10" x 10"
11" x 10"
4
4
683
768
341
384
12.8
13.7
15
15
N/A
N/A
*CSS96
*CSS96
1205DNA
120,000
114,000
95
45 - 75
3"
6
3 - 5
11" x 11"
4
844
422
13.7
15
N/A
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

*css96 series

Table of Contents