Connecting Microphones to the
AUDIO IN Connectors
You can connect up to two monaural
microphones to the AUDIO IN CH-1/CH-2
connectors, using an optional CAC-12
Microphone Holder.
The following is the procedure for attaching an
electret condenser microphone such as the ECM-
674/678.
On how to attach the CAC-12, refer to the operation
manual for the CAC-12.
1
Attach the electret condenser
microphone.
1 Loosen the ball joint lock lever.
2 Wind the microphone spacer (sheet
type, supplied with the microphone)
around the microphone, while peeling
off the protective sheets on both sides
of the microphone spacer.
3 Place the microphone in the holder so
that "UP" is at the top.
4 Close the microphone holder.
5 Tighten the screw.
6 Position so that the microphone does
not interfere with the viewfinder and
tighten the ball joint lock lever.
2
3
Microphone
4
Connect the microphone cable to the
AUDIO IN CH-1 or CH-2 connector.
Set the switches as follows.
• Set the AUDIO IN selectors indicated
below, depending on the power supply type
of the microphone.
Internal power supply: MIC
External power supply: +48V
• Set the AUDIO IN CH1/CH2 switch for the
channel to which the microphone is
connected to REAR.
1 AUDIO IN selectors
2 Monaural microphone
3 AUDIO IN CH1/CH2 switches
4 To AUDIO IN CH-1 or CH-2 connector
Switch the input level to match the
sensitivity of the microphone used.
Switch the input level by changing the setting of
MAINTENANCE >Audio >Rear MIC CH1/
CH2 Ref in the setup menu (factory default
setting is –60 dB). For details, see page 136.