1
2
3
4
1. Continuos nailing
2. Intermittent nailing
3. Change lever
4. Trigger lock
1
2
3
4
1. Hammer
2. Small rod
3. Ejection port
4. Driver
1. Pliers
2. Slot
For No. 1 method, set the change lever to the "Intermittent Nailing"
004307
position. For No. 2 method, set the change lever to the "Continuous
Nailing" position. After using the change lever to change the nailing
method, always make sure that the change lever is properly set to the
position for the desired nailing method.
Anti dry fire mechanism
This tool is equipped with an anti dry fire mechanism. When there are a
few nails remaining in the magazine, the contact arm will be locked in the
undepressed position to prevent the tool from being activated. Load
more nails to resume operation.
Jammed nailer
CAUTION:
Always lock the trigger, disconnect the hose and remove the nails from
the magazine before cleaning a jam.
When the nailer becomes jammed, do as follows:
Insert a small rod or the like into the ejection port and tap it with a
004308
hammer to retract the driver. Use pliers to bend the jammed nail so that
the nail head comes out of the slot in the driver guide. Then remove the
jammed nail.
004309
1
2
9