Power Requirement - National Instruments Relay Module SCC-RLY01 User Manual

Relay module
Hide thumbs Also See for Relay Module SCC-RLY01:
Table of Contents

Advertisement

The SCC-RLY01 module is derated to 30 V maximum switching voltage in the
Caution
SC-2345 carrier regardless of any other voltage markings found on the SCC-RLY01
module case.

Power Requirement

Physical
1
Excluding contact bounce time
© National Instruments Corporation
Signal bandwidth.................................... DC to 400 Hz
Contact resistance .................................. 30 mΩ max
Switching time
Operate time (NC to NO)................ 5 ms (10 ms max)
Release time (NO to NC)................ 4 ms (5 ms max)
Maximum operating speed..................... 30 cps at rated load
Contact lifetime...................................... 5 × 10
Digital power.......................................... 300 mW max
+5 V........................................................ 60 mA max
1.87 cm
(0.74 in.)
Weight .................................................... 37 g (1.3 oz)
(minimum)
7.93 cm
(3.12 in.)
-
Figure 3. SCC
RLY01 Dimensions
5
1
7
operations at 180 cpm
3.55 cm
(1.4 in.)
SCC-RLY01 Relay Module User Guide

Advertisement