Indications Of The Pilot Lamp (Uc18Ygsl); Indications Of The Pilot Lamp (Uc18Yrsl); How To Make The Batteries Perform Longer; Charging Time (At 20°C) - Hitachi CG 14DSDL Handling Instructions Manual

Cordless grass trimmer
Hide thumbs Also See for CG 14DSDL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
Before
charging
While
charging
Charging
Pilot lamp
complete
(red)
Overheat
standby
Charging
impossible
Before
charging
While
charging
Pilot lamp
(red)
Charging
complete
Charging
impossible
Pilot lamp
Overheat
(green)
standby
(2) Regarding the temperatures of the rechargeable
battery
The temperatures for rechargeable batteries are as
shown in the Table 2, and batteries that have become
hot should be cooled for a while before being recharged.
Table 2 Recharging ranges of batteries
Temperatures at which the battery can be recharged
0°C – 50°C
(3) Regarding recharging time
Table 3 shows the recharging time required according
to the type of battery.
Table 3 Charging time (At 20°C)
Charger
UC18YGSL
Battery
BSL1430
Approx. 90 min.
BSL1830
Approx. 90 min.
BSL1440
Approx. 120 min.
BSL1840
Approx. 120 min.
NOTE
The recharging time may vary according to the ambient
temperature.

Indications of the pilot lamp (UC18YGSL)

Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Blinks
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Blinks
Lights for 1 second. Does not light for 0.5
seconds. (off for 0.5 seconds)
Blinks
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Flickers

Indications of the pilot lamp (UC18YRSL)

Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Blinks
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Blinks
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Flickers
Lights continuously
Lights
UC18YRSL
Approx. 45 min.
Approx. 45 min.
Approx. 60 min.
Approx. 60 min.
Table 1
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might be
low when using them the fi rst and second time. This is
a temporary phenomenon, and normal time required for
recharging will be restored by recharging the batteries
2 – 3 times.

How to make the batteries perform longer

(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
English
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
Malfunction in the
battery or the charger
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
19