Lectrosonics DR Receiver/DB Transmitter Instruction Manual page 16

Digital secure wireless system
Table of Contents

Advertisement

DSW Digital Wireless System
Powering On in Operating Mode
Press and hold the Power Button
the LCD progresses from 1 to 3. When you release the
button, the unit will be operational with the RF output
turned on and the Main Window displayed.
Steve
Hold
for
MUTE
Rf On
494.500
...3
-40
Powering On in Standby Mode
Pressing the Power Button
the counter has reached 3 will turn the unit on with
the RF output turned off. In this Standby Mode the
menus can be browsed to make settings and adjust-
ments without the risk of interfering with other wireless
systems nearby.
Release Power
Hold
Button before
for
the counter
reaches 3 to
Rf On
enter standby
...1
After settings and adjustments are made, turn the unit
off by pressing and holding the power button until a
countdown on the LCD is completed.
NOTE: Also see the topic entitled Power Menu for
other options.
Powering Off
From any screen, power can be
Powering
turned off by holding the Power
O . . .
Button
countdown, selecting Pwr Off in the
power menu, or with the program-
mable switch (if it is configured for
1
this function).
If the power button is released, or the top panel switch
is turned back on again before the countdown is com-
pleted, the unit will remain turned on and the LCD will
return to the same screen or menu that was displayed
previously.
NOTE: If the programmable switch is in the OFF
position, power can still be turned on with the power
button.
16
until a counter on
RF
indicator
-20
0
and releasing it before
Steve
MUTE
494.500
mode
-40
-20
RF indicator blinks
in and waiting for the
Power Menu
Pressing the power button
on will display a menu with several options:
• Resume returns to the previous screen and operat-
ing state.
• Rf On? opens a dialogue screen with options to turn
the RF output on or off.
• AutoOn? opens a dialogue screen with options to
either automatically restore power after batteries
have been replaced, or leave the unit turned off after
batteries have been replaced.
• Pwr Off starts the power off sequence countdown.
Resume
Rf On?
AutoOn?
Pwr Off
The other two menu items will open a screen asking
for a Yes or No answer.
Resume
Rf On?
AutoOn?
0
Pwr Off
Resume
Rf On?
AutoOn?
Pwr Off
when the unit is turned
Resume
Resume and Pwr Off
Rf On?
will execute
the command
AutoOn?
immediately
Pwr Off
Rf On?
No
Yes
AutoOn?
No
Yes
LECTROSONICS, INC.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DR Receiver/DB Transmitter and is the answer not in the manual?

Questions and answers

Table of Contents