13.2 Configure the settings relating to the camera
action on alarm occurrence [Alarm]
Click the [Alarm] tab on the "Alarm" page. (®page 48, page 50)
The settings relating to the camera action at an alarm occurrence can be configured in this section. Refer to
pages 135, 139 and 142 for further information about the settings relating to the alarm, the alarm image and
the alarm output terminal.
Camera action on alarm
[Terminal alarm 1]
Select an action to be taken when a terminal alarm 1 is detected from the following.
Off: Does not take any action even when a terminal alarm 1 is detected.
1-256: If a previously registered preset position is selected, when a terminal alarm 1 is detected, the camera
will move to that position.
Auto track: When a terminal alarm 1 is detected, the camera will start the auto tracking.
Patrol 1: When a terminal alarm 1 is detected, the camera will start the patrol.
* If Patrol 1 is not registered it is not displayed on the screen.
Default: Off
[Terminal alarm 2]
Select an action to be taken when a terminal alarm 2 is detected from the following.
Off: Does not take any action even when a terminal alarm 2 is detected.
1-256: If a previously registered preset position is selected, when a terminal alarm 2 is detected, the camera
will move to that position.
Auto track: When a terminal alarm 2 is detected, the camera will start the auto tracking.
Patrol 2: When a terminal alarm 2 is detected, the camera will start the patrol.