14. White Balance, Luminance Adjustment
Equipment:
PC x 1, Chroma2325 (or equivalent instrument), CA-210 x 1, W/B record card x 1
Equipment installation:
1. Connect analyzer CA-210 to PC by USB connector, install driver program CA-SDK Ver4.00 for CA-210 and
restart PC after finish installing
2. Install Port95NT drive program, set PC printer connector mode as ECP mode and restart PC after finish installing.
3. Connect tool as follow:
Preparation before adjustment:
a. Monitor should be warmed up for more than half an hour.
b. Make sure that the tools are connected right and drive programs have been installed OK.
c. Connect the signal cable, barcode reader, and connected card.
Adjustment processes
a. Press the power of CA-210, shut off the lens, press 0-Cal and open the lens after analyzer reset.
b. Open white balance adjustment program, select the right parameter according with the program and click OK.
c. Make sure that the lens of CA-210 aims at the center of the screen, then click START to adjust.
d. After finish adjusting, the adjustment program displays pass, and the START button changes for NEXT, which
means that you can adjust another monitor.
To PC LPT
Chroma Equipment
+12V DC power
Testing monitor