Non Zero Clearance Box ALL INSTRUCTIONS TO COMPLY WITH NZS5261:2003 Due to continued product improvement, The Fireplace Ltd reserves the right to change product specifications without prior notification instructions ArE for instAllAtion into A complEtE mAsonry firEplAcE construction i.E: cAvity And chimnEy chAsE (no comBustiBlEs)
Page 2
JEtmAstEr iGc BoX dimEnsions 2.mG.2B Table 1 Model 200/250 250/300 1050 1050 1150 1100 250/300 1200 1200 1300 1250 250/300 1500 1500 1600 1550 250/300 Dimensions in mm Fig. 1 Fig. 2 Gather Gather Convector Back Front GAs trAy opErAtinG options Table 2 Manual *M.V.
Page 3
2.mG.2c cAvity / frAminG prEpArAtion Refer to Table 3 for the minimum cavity dimensions and temporary lintel height measurements, until the convector box and flue system is installed. note: Temporary lintel height is measured from finished floor protector level. Ensure suitable air vents (min. 2 x 80mm diameter or equivalent) in place to vent firebox cavity - these maybe located in the floor or in the side wall space;...
2.mG.2d firEBoX instAllAtion 1. Fit and seal gather, using fire cement (exhaust cement) and bolts (supplied), to the convector box. Note: Pop rivet back of gather to convector box if required. 2. Locate and position convector box and gather in cavity. 3.
Page 5
2.mG.2E rEcEss plAn Fig. 5 min 2x80 mm diam. or equal square or rectangle shape area wall or floor mounted air vents Allow gas line (Optional) into firebox Air Vents Air Vents B + recessed maximum 100 mm recessed Masonry or Hebel block In Fill where requires Hearth rEcEss sEction...
Discuss Bird Proofing needs with your installer. N.B. in extreme wind areas it may be necessary to consult The Fireplace Ltd or your local agent for further technical assistance. 10. If flue is concealed in a chase, allow for air vents (2 x 80mm diam. or equivalent) at the highest possible point on the chimney chase or alternatively, allow a min 25mm air space between the casing cover spigot and the outer casing.
2.mG.2G fluE pEnEtrAtion Fig. 9 Cowl Casing Cover Air Gap Top Spider External Requirements Refer to NZS 5261:2003 Approved Flashings to S2 Minimum 25mm gap between flue pipe casing & combustible surface Air Vents flue pipe min. 2 x 80mm diam. or equal square or flue pipe casing rectangle shape area...
Page 8
2.mG.2h chimnEy chAsE minimum trim out Table 4 MODEL FLUE SYSTEM MINIMUM TRIM OUT DIMENSION X (min) Y (min) 200/250 250/300 1050 250/300 1200 250/300 1500 250/300 Dimensions in mm note: A minimum 25mm clearance from flue pipe casing to combustible material must be maintained. Fig.