Advertisement

OMRON HEALTHCARE Co., Ltd.
Manufacturer
53, Kunotsubo, Terado-cho, Muko, KYOTO,
617-0002 JAPAN
EU-representative
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS
Asia Pacific HQ
OMRON HEALTHCARE SINGAPORE PTE LTD.
438A Alexandra Road, #05-05/08
Alexandra Technopark, Singapore 119967
www.omronhealthcare-ap.com
Production facility
Binh Duong Province, VIETNAM
Automatic Blood Pressure Monitor
Model HEM-7280T
Instruction Manual
3262572-4B
HEM-7280T-AP_B_M03_151013.pdf
Package includes:
14G1648

Advertisement

Table of Contents
loading

Summary of Contents for Omron HEM-7280T

  • Page 1 EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS Automatic Blood Pressure Monitor Model HEM-7280T Asia Pacific HQ OMRON HEALTHCARE SINGAPORE PTE LTD. 438A Alexandra Road, #05-05/08 Instruction Manual Alexandra Technopark, Singapore 119967 www.omronhealthcare-ap.com Production facility Binh Duong Province, VIETNAM...
  • Page 2: Important Safety Information

    HEM-7280T-AP_B_M.fm Page 1 Tuesday, October 13, 2015 2:51 PM Important Safety Information Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician.
  • Page 3 HEM-7280T-AP_B_M.fm Page 2 Tuesday, October 13, 2015 2:51 PM Important Safety Information Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
  • Page 4 Wipe the dust off from the power plug. Unplug monitor when not in use. Disconnect the power plug before cleaning. Use only an OMRON AC adapter designed for this device. Use of unsupported adapters may damage and/or may be hazardous to the device. (Battery Usage) Do not insert the batteries with their polarities incorrectly aligned.
  • Page 5: Know Your Device

    HEM-7280T-AP_B_M.fm Page 4 Tuesday, October 13, 2015 2:51 PM 1. Know Your Device Open the rear cover page to read the following: The letter identifiers on the rear cover page correspond to those in the body of this page. Monitor...
  • Page 6: Display Symbols

    HEM-7280T-AP_B_M.fm Page 5 Tuesday, October 13, 2015 2:51 PM 1. Know Your Device 1.1 Display Symbols Irregular Heartbeat Symbol ( Normal Heartbeat When the monitor detects an irregular rhythm two or more times during the Pulse measurement, the irregular heartbeat symbol will appear on the display with Blood pressure the measurement values.
  • Page 7: Before Taking A Measurement

    HEM-7280T-AP_B_M.fm Page 6 Tuesday, October 13, 2015 2:51 PM 1. Know Your Device Blood Pressure Level Indicator (Colour) If your Systolic Blood Pressure is 135 mmHg or above and/or the Diastolic Blood Pressure is 85 mmHg or above, the blood pressure level indicator (colour) will light in “orange” when the measurement result is displayed.
  • Page 8: Preparation

    HEM-7280T-AP_B_M.fm Page 7 Tuesday, October 13, 2015 2:51 PM 2. Preparation 2.1 Battery Installation Remove the battery cover. Insert 4 “AA” batteries as indicated in the battery compartment. Replace the battery cover. Notes: • Please keep the batteries in your device all the time when you use an optional AC adapter.
  • Page 9: Pairing This Device With A Smartphone

    HEM-7280T-AP_B_M.fm Page 8 Tuesday, October 13, 2015 2:51 PM 2. Preparation 2.2 Pairing this Device with a Smartphone To begin using the OMRON connect app for the first time, please visit www.omronconnect.com/setup for the initial set-up instructions. List of Compatible Smartphones at: www.omronconnect.com/devices For details, visit: www.omronconnect.com...
  • Page 10 HEM-7280T-AP_B_M.fm Page 9 Tuesday, October 13, 2015 2:51 PM 2. Preparation Press the connection button for more than 2 seconds. The connection symbol ( ) and the “P” flashes on the device’s display. Open the app on your smartphone and follow the...
  • Page 11 HEM-7280T-AP_B_M.fm Page 10 Tuesday, October 13, 2015 2:51 PM 2. Preparation Confirm if the device is connected successfully. When the device is connected successfully to the smartphone, “OK” symbol and the display shown on the right will flash. The monitor will automatically turn off without any operations.
  • Page 12 HEM-7280T-AP_B_M.fm Page 11 Thursday, October 15, 2015 4:45 PM 2. Preparation To Set the Date and Time Manually The date and time will be automatically set when paired with your smartphone. To set manually, follow the instructions below. Press the connection button.
  • Page 13: Using The Device

    • The blood pressure can differ between the right arm and the left arm, and the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between both arms differ substantially, please check with your physician which arm to use for your...
  • Page 14: How To Sit Correctly

    HEM-7280T-AP_B_M.fm Page 13 Tuesday, October 13, 2015 2:51 PM 3. Using the Device 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. Avoid bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement.
  • Page 15: Taking A Measurement

    HEM-7280T-AP_B_M.fm Page 14 Tuesday, October 13, 2015 2:51 PM 3. Using the Device 3.3 Taking a Measurement Check if the date and time are correct on the display before taking the measurement. If the date and time settings are necessary, refer to “To Set the Date and Time Manually”...
  • Page 16 HEM-7280T-AP_B_M.fm Page 15 Tuesday, October 13, 2015 2:51 PM 3. Using the Device Remove the arm cuff. Press the START/STOP button to turn the monitor off. The monitor automatically stores the measurement result in its memory. It will automatically turn off after 2 minutes without any operations.
  • Page 17 HEM-7280T-AP_B_M.fm Page 16 Tuesday, October 13, 2015 2:51 PM 3. Using the Device Confirm with your device if the measurement data is transferred successfully. If the display on the right is shown, the data is transferred successfully. When “Err” appears, refer to “Data cannot be sent.” in section...
  • Page 18 HEM-7280T-AP_B_M.fm Page 17 Tuesday, October 13, 2015 2:51 PM 3. Using the Device To Use the Guest Mode The monitor stores measurement values for 2 users in the memory. The guest mode can be used to take a single measurement for another user. No measurement values are stored in the memory when the guest mode is selected.
  • Page 19: Using The Memory Function

    HEM-7280T-AP_B_M.fm Page 18 Tuesday, October 13, 2015 2:51 PM 3. Using the Device 3.4 Using the Memory Function The monitor automatically stores the results up to 100 sets for each user (1 and 2). It can also calculate an average value based on the last 3 measurement values taken within 10 minutes.
  • Page 20 HEM-7280T-AP_B_M.fm Page 19 Tuesday, October 13, 2015 2:51 PM 3. Using the Device To View the Average Value Select your USER ID (1 or 2). Press and hold the button for more than 3 seconds. Notes: • If the previous measurement was taken without setting the date and time, the average value is not calculated.
  • Page 21 HEM-7280T-AP_B_M.fm Page 20 Tuesday, October 13, 2015 2:51 PM 3. Using the Device Press the button. The morning average for “THIS WEEK” appears on the display. Note: The morning hypertension symbol ( ) appears if the morning weekly average is above 134/84 mmHg.
  • Page 22 HEM-7280T-AP_B_M.fm Page 21 Tuesday, October 13, 2015 2:51 PM 3. Using the Device Morning Weekly Average Measurements of the morning This is the average for the Sunday Monday Tuesday Wednesday Thursday Friday Saturday 4:00 measurements taken during the morning First measurement of...
  • Page 23: Deleting All Values Stored In Memory

    HEM-7280T-AP_B_M.fm Page 22 Tuesday, October 13, 2015 2:51 PM 3. Using the Device To Delete All the Values Stored in Memory The values stored in the memory are deleted by USER ID. Select your USER ID (1 or 2). Press the Memory button while the memory symbol ( ) appears.
  • Page 24: Turning "Off" The Bluetooth

    HEM-7280T-AP_B_M.fm Page 23 Tuesday, October 13, 2015 2:51 PM 3. Using the Device 3.5 Turning “OFF” the Bluetooth ® ® Turn off the Bluetooth of the monitor in the following areas where use of wireless equipment is prohibited. • On aircraft •...
  • Page 25 HEM-7280T-AP_B_M.fm Page 24 Tuesday, October 13, 2015 2:51 PM 3. Using the Device ® To turn “ON” the Bluetooth Make sure that the power has been off before starting the instructions below. Press and hold the connection button for more than 10 seconds.
  • Page 26: Initial Setting Of The Monitor

    HEM-7280T-AP_B_M.fm Page 25 Tuesday, October 13, 2015 2:51 PM 3. Using the Device 3.6 Initial Setting of the Monitor To delete all the information stored in your monitor, follow the instructions below. Make sure that the monitor’s power has been off.
  • Page 27: Error Messages And Troubleshooting

    HEM-7280T-AP_B_M.fm Page 26 Tuesday, October 13, 2015 2:51 PM 4. Error Messages and Troubleshooting 4.1 Error Messages Display Cause Solution Remove the arm cuff. Wait 2-3 minutes and then take another measurement. Irregular heartbeats are detected. Repeat the steps in section 3.3. If this error continues to appear, contact your physician.
  • Page 28 HEM-7280T-AP_B_M.fm Page 27 Tuesday, October 13, 2015 2:51 PM 4. Error Messages and Troubleshooting Display Cause Solution Insert the air plug securely. Air plug is disconnected. Refer to section 3.1. Apply the arm cuff tighter. Arm cuff is applied too loosely.
  • Page 29: Troubleshooting

    HEM-7280T-AP_B_M.fm Page 28 Tuesday, October 13, 2015 2:51 PM 4. Error Messages and Troubleshooting 4.2 Troubleshooting Problem Cause Solution Apply the arm cuff tighter. Arm cuff is applied too loosely. Refer to section 3.1. Remain still and do not talk during Movement or talking during measurement.
  • Page 30 HEM-7280T-AP_B_M.fm Page 29 Tuesday, October 13, 2015 2:51 PM 4. Error Messages and Troubleshooting Problem Cause Solution Replace the batteries with new ones. The batteries are depleted. Refer to section 2.1. Nothing happens when you press the buttons. Insert the batteries with the correct The batteries have been inserted (+/-) polarity.
  • Page 31 HEM-7280T-AP_B_M.fm Page 30 Tuesday, October 13, 2015 2:51 PM 4. Error Messages and Troubleshooting Problem Cause Solution • Press the START/STOP button and repeat measurement. • Replace the batteries with new ones. Other problems. If the problem continues, contact your local OMRON representative.
  • Page 32: Maintenance And Storage

    • Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the device or components. Consult your local OMRON representative. Calibration and Service • The accuracy of this device has been carefully tested and is designed for a long service life.
  • Page 33: Storage

    HEM-7280T-AP_B_M.fm Page 32 Tuesday, October 13, 2015 2:51 PM 5. Maintenance and Storage 5.2 Storage Keep the device in its storage case when not in use. Unplug the air plug from the air jack. Gently fold the air tube into the arm cuff.
  • Page 34 HEM-CS24 HEM-RML31 Model: 60240HW5SW Note: Please check with your local OMRON representatives for the appropriate optional parts. Using the Optional AC Adapter If AC adapter is used without batteries and unplug the AC adapter from the electrical outlet, the data and time are reset.
  • Page 35: Technical Data

    HEM-7280T-AP_B_M.fm Page 34 Tuesday, October 13, 2015 2:51 PM 7. Technical Data Product description Automatic Blood Pressure Monitor Model HEM-7280T Display LCD digital display Measurement method Oscillometric method Transmission method Bluetooth ® Version 4.0 (Low Energy support) Measurement range Pressure: 0 to 299 mmHg Pulse: 40 to 180 beats / min.
  • Page 36 • This OMRON device is produced under the strict quality system of OMRON HEALTHCARE Co., Ltd., Japan. The core component for OMRON devices, which is the Pressure Sensor, is produced in Japan. This Product operates in the unlicensed ISM band at 2.4 GHz. In case this Product is used...
  • Page 37 HEM-7280T-AP_B_M.fm Page 36 Tuesday, October 13, 2015 2:51 PM 7. Technical Data Correct Disposal of This Product (Waste Electrical & Electronic Equipment) This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life.
  • Page 38: Pressure

    HEM-7280T-AP_B_M.fm Page 37 Tuesday, October 13, 2015 2:51 PM 8. Some Useful Information about Blood Pressure What is Blood Pressure? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cycle.
  • Page 39 HEM-7280T-AP_B_M.fm Page 38 Tuesday, October 13, 2015 2:51 PM...
  • Page 40 HEM-7280T-AP_B_M.fm Page 39 Tuesday, October 13, 2015 2:51 PM...
  • Page 41 HEM-7280T-AP_B_M.fm Page 40 Tuesday, October 13, 2015 2:51 PM...
  • Page 42: Table Of Contents

    Contents Thank you for purchasing the OMRON HEM-7280T Automatic Blood Pressure Monitor. Your new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.

Table of Contents