13

Top feed stroke

.05.15
Requirement
With the stitch length set at "3" and the adjustment gauge 12 fitted, at its t.d.c. the top
feed dog 2 should be 2 mm from the needle plate.
5
7
8
10
Fig. 13 - 16
Lower the presser foot 1 onto the needle plate.
Set stitch length at "3".
By turning the balance wheel bring top feed dog 2 to its t.d.c.
Turn eccentric pin 3 (screw 4) so that its greatest eccentricity points towards the needle.
Bring bolt 5 (nut 6) ) ) ) ) down to rest in the elongated hole of lever 7. . . . .
Adjust lever 8 (screw 9) for the pre-adjustment of the distance between the top feed dog
2 and the needle plate.
Adjust eccentric pin 10 (screw 11) according to the requirement.
12
54-033
4
3
1
1
5
6
9
8
11
Adjustment