Electrolux EI30BM55HB Technical & Service Manual page 28

Hide thumbs Also See for EI30BM55HB:
Table of Contents

Advertisement

Troubleshooting
Procedure
Letter
D
HIGH VOLTAGE CAPACITOR TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input
leads and check for short or open between the terminals using an ohmmeter.
Checking with a high ohm scale, if the high voltage capacitor is normal, the meter will indi-
cate continuity for a short time and should indicate an open circuit once the capacitor is
charged. If the above is not the case, check the capacitor with an ohmmeter to see if it is
shorted between either of the terminals and case. If it is shorted, replace the capacitor.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
E
THERMAL CUT-OUT AND TEMPERATURE FUSE TEST
1. CAVITY THERMAL CUT-OUT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. A continuity check across the thermal cut-out terminals should indicate a closed circuit
unless the temperature of the thermal cut-out reaches approximately 293°F(145°C). An open
thermal cut-out indicates overheating of the oven, exchange the oven thermal cut-out and
check inside of oven cavity and for improper setting of cooking time or operation of control
unit. Check for restricted air flow through the vent holes of the oven cavity,
especially the cooling fan and air guide.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
2. MAGNETRON TEMPERATURE FUSE TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. A continuity check across the magnetron temperature fuse terminals should indicate a
closed circuit unless the temperature of the magnetron temperature fuse reaches
approximately 302°F(150°C). An open magnetron temperature fuse indicates overheating of
the magnetron. Check for restricted air flow to the magnetron, especially the cooling fan air
guide.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
CAUTION:
Component Test
IF THE TEMPERATURE FUSE INDICATES AN OPEN CIRCUIT AT ROOM
TEMPERATURE, REPLACE TEMPERATURE FUSE.