Asko D1976 Service Manual page 4

Hide thumbs Also See for D1976:
Table of Contents

Advertisement

Date
2000-06
EXTENDING FAN COOLING TIME
To extend the fan cooling time, press S1 five times then press one of the following:
S5 for 30 extra minutes
S4 for normal fan cooling time
SETTING AN EXTRA RINSE
To add an extra rinse to the Pots and Pans, Super, Normal and Light wash programs, press S2 five
times then press one of the following:
S5 for an extra rinse
S4 for the normal number of rinses
SETTING CHILD-SAFE START FUNCTION
The start function can be reprogrammed so that the Start button must be pressed in for 3 seconds to
start the programs. To do this, press S4 five times then press one of the following:
S5 to get a prolonged start function or
S4 to get a normal start function.
SETTING PUMP-OUT TIME
If it's necessary to reprogram the pump-out time, you can do so by pressing S3 five times then pressing
one of the following:
Press:
S3
S4
S5
S6
S7
SETTING INLET TIME
You can reprogram the inlet time on level controlled and time controlled inlets. To do this, press S5 five
times then press one of the following:
Press:
S3
S4
S5
S6
S7
S8
PROGRAMS
S = Pushbutton switch
to get an outlet time of:
20 seconds
25 seconds (factory setting)
35 seconds
45 seconds
85 seconds
to get an inlet time of:
45 seconds (factory setting)
56 seconds
68 seconds
90 seconds
113 seconds
180 seconds
Model D1976