Page 1
XR20M1280 EVALUATION BOARD USER’S MANUAL REV. 1.0.0 INTRODUCTION This user’s manual is for the XR20M1280 evaluation board. Table 1 shows the different devices and packages that the evaluation board supports. This user’s manual will describe the hardware setup required to operate the different packages.
Page 2
XR20M1280 EVALUATION BOARD USER’S MANUAL REV. 1.0.0 3: J XR20M1280IL24 ABLE UMPER ETTINGS UMPERS UNCTIONS OMMENTS Selects the supply voltage for GPIO15- Not used for XR20M1280IL24 GPIO4 (VCC_GPIO) Jumper in 1&2 selects 3.3V (default) Jumper in 3&4 selects 2.5V Jumper in 5&6 selects 1.8V Selects 5V source for regulator to 1.8V...
Page 3
XR20M1280 EVALUATION BOARD USER’S MANUAL REV. 1.0.0 3: J XR20M1280IL24 ABLE UMPER ETTINGS UMPERS UNCTIONS OMMENTS C Address Select (A1) For I C mode, only one jumper should be selected. See 1&2 = VCC XR20M1280 datasheet for I C addressing.
Page 4
XR20M1280 EVALUATION BOARD USER’S MANUAL REV. 1.0.0 1.2.2 XR20M1280IL32 The following jumpers apply to the XR20M1280IL32: 4: J XR20M1280IL32 ABLE UMPER ETTINGS UMPERS UNCTIONS OMMENTS Selects the supply voltage for UART Jumper in 1&2 selects 3.3V (default) modem I/Os including GPIO3-GPIO0 Jumper in 3&4 selects 2.5V...
Page 5
XR20M1280 EVALUATION BOARD USER’S MANUAL REV. 1.0.0 4: J XR20M1280IL32 ABLE UMPER ETTINGS UMPERS UNCTIONS OMMENTS SLEEP/PWRDN pin Header installed, no jumpers installed (default) Refer to the datasheet for the behavior of this pin UART Reset input Jumper on 1&2 selects J2 as hardware reset Jumper on 2&3 selects external reset from J9 pin 32 (default)
Page 6
XR20M1280 EVALUATION BOARD USER’S MANUAL REV. 1.0.0 1.2.3 XR20M1280IL40 The following jumpers apply to the XR20M1280IL40: 5: J XR20M1280IL40 ABLE UMPER ETTINGS UMPERS UNCTIONS OMMENTS Selects the supply voltage for UART Jumper in 1&2 selects 3.3V (default) modem I/Os including GPIO3-GPIO0 Jumper in 3&4 selects 2.5V...
Page 7
XR20M1280 EVALUATION BOARD USER’S MANUAL REV. 1.0.0 5: J XR20M1280IL40 ABLE UMPER ETTINGS UMPERS UNCTIONS OMMENTS Enable/Disable IR mode at power-up J44 in enables IR mode at power-up (can be enabled/disabled in software after J44 out disables IR mode at power-up...
Page 8
For a sample initialization routine or if there are any questions, send an e-mail to uarttechsupport@exar.com. NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement.