14. Installation

Connecting the Cables

Indoor
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually
according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No.
are the same as those of the indoor unit.)
• The circuit diagram is subject to change without notice.
• The earth wire should be longer than the common wires.
• When installing, refer to the circuit diagram on the front panel.
• Connect the wires firmly so that they may not be pulled out easily.
• Connect the wires according to color codes, referring to the wiring diagram.
If a power plug is not used, provide a circuit
breaker between power source and the unit as
shown by.
The power cord connected to the Indoor unit should be selected according to the following specifications(Type "B"
approved by HAR or SAA).
NORMAL CROSS
-SECTIONAL AREA
Cable Type(B)
The power connecting cable connecting the indoor and outdoor unit should be selected according to the following
specifications (Type "B" approved by HAR or SAA).
NORMAL CROSS
9k S4 / 12k S4 9k~18k 18k S3 / 24k 30k~36k
-SECTIONAL AREA
Cable Type(B)
H07RN-F H07RN-F H07RN-F H07RN-F
100
2008 Product Data
(mm
Grade
9k~12k
12k SU / 18k 18k S3 / 24k~36k
1.0
1.5
2.5
H05VV-F
H05VV-F
H05VV-F
(mm
Grade
1.0
1.5
2.5
0.75
Main power source
Air
Conditioner
2
)
2
)
Circuit Breaker
Use a circuit breake
or time delay fuse.