Drolet Spark DB03400 Installation And Operation Manual page 36

Table of Contents

Advertisement

Spark Installation and Operation Manual
Clearances with ceiling (L) lowered to 68" (173 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH SINGLE
WALL PIPE CONNECTOR)
CANADA
A
15½" (394 mm)
B
18" (457 mm)
C
12" (305 mm)
K
48" (1220 mm)
L
68" (173 cm)
Note: These clearances are also valid for an alcove installation.
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
D
18" (457 mm)
E
26¼" (667 mm)
F
20" (508 mm)
*The pipe distances listed in this table refer to the distances obtained when the
stove is installed in accordance with the appliance clearances above mentioned.
However, you can install the stove at reduced clearances; follow the instructions in
Section 8.4: Reducing Wall and Ceiling Clearances Safely. Where they are followed,
the new distance of the pipe to combustible materials must be respected in the
appropriate certification of the pipe.
36
USA
15" (381 mm)
18" (457 mm)
12" (305 mm)
48" (1220 mm)
68" (173 cm)
USA
17½" (455 mm)
26¼" (667 mm)
20" (508 mm)
APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE
WALL PIPE CONNECTOR)
CANADA
A
12" (305 mm)
B
18" (457 mm)
C
10" (254 mm)
K
48" (1220 mm)
L
68" (173 cm)
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
D
14½" (368 mm)
E
26¼" (667 mm)
F
18" (457 mm)
USA
12" (305 mm)
18" (457 mm)
10" (254 mm)
48" (1220 mm)
68" (173 cm)
USA
14½" (368 mm)
26¼" (667 mm)
18" (457 mm)