MEX-BT4100E/BT4100P/BT4100U/BT4150U
Ver. 1.1
NOTE THE MAIN BOARD OR SYSTEM CONTROLLER
(IC501) REPLACING
When the MAIN board or system controller (IC501) is replaced,
the destination setting is necessary.
1. Destination Setting
Set destination according to the procedure below.
1-1. Setting the Destination Code
1. In the state of source off (the clock is displayed), enter the test
mode by pressing the buttons in order of the [SHUF 4] t
[MIC/ZAP 5] t [PAUSE 6] (press only the [PAUSE 6] button
for two seconds).
2. In the state in which the system controller version is displayed
on the liquid crystal display (refer to following fi gure), enter
the destination setting mode by pressing the buttons in order
of the [SEEK+
] t [
> M
TER/MENU/ APP].
(Displayed characters/values in the following fi gure are ex-
ample)
System controller version
SHUF
3. Input the alphanumeric character of 12 digits of "F XXXXXX"
displayed on the liquid crystal display, and execute the destina-
tion setting.
Note: Refer to following "1-3. Entering the Destination Code" for opera-
tion method.
4. The resetting operation is executed by pressing the [ OFF
SOURCE] button for 1 second after the setting ends, and the
unit returns to the normal condition.
1-2. Display in Destination Setting Mode
(Displayed characters/values in the following fi gure are example)
Destination code
SHUF
OP5 OP4 OP3 OP2 OP1 OP0
12 digit
1-3. Entering the Destination Code
Method of operation by main unit
1. Rotate the control dial, and select the alphanumeric character
of "0 to F".
2. The digit advances by pressing the [PUSH ENTER/MENU/
APP] or [SEEK+
] button.
> M
The digit returns by pressing the [
SEEK–] button.
3. The setting is completed by pressing the [PUSH ENTER/
MENU/ APP] button, and the initialization operation is done.
4
SEEK–] t [PUSH EN-
m .
MODE] or [
m .
Method of operation by remote commander
1. Press the [ ] or [ ] button, and select the alphanumeric char-
acter of "0 to F".
2. The digit advances by pressing the [
The digit returns by pressing the [
3. The setting is completed by pressing the [ENTER] button, and
the initialization operation is done.
1-4. Destination Code
Model
Destination
MEX-BT4100E
Russian
MEX-BT4100P
US, Canadian
MEX-BT4100U
AEP, UK
MEX-BT4150U
E, Mexican
MEX-BT4150U
Saudi Arabia
2. Confi rmation After Destination Setting
Execute the following operation after completing the destination
setting, and confi rm a correct destination was set.
Destination setting checking method:
1. In the state of source off (the clock is displayed on the liquid
crystal display), enter the test mode by pressing the buttons in
order of the [SHUF 4] t [MIC/ZAP 5] t [PAUSE 6] (press
only the [PAUSE 6] button for two seconds).
2. In the state in which the system controller version is displayed
on the liquid crystal display (refer to following fi gure), enter
the destination setting value display mode by pressing the [
SCRL DSPL] button three times.
(Displayed characters/values in the following fi gure are ex-
ample)
System controller version
SHUF
3. Confi rm the alphanumeric character of 12 digits in liquid crys-
tal display is an value correctly input.
(Displayed characters/values in the following fi gure are ex-
ample)
Destination code
SHUF
OP5 OP4 OP3 OP2 OP1 OP0
12 digit
4. The resetting operation is executed by pressing the [ OFF
SOURCE] button for 1 second after the confi rming ends, and
the unit returns to the normal condition.
] button.
] button.
OP5 OP4 OP3 OP2 OP1 OP0
C
C
1
5
8
7
5
E
1
5
6
2
4
C
1
5
7
1
4
C
1
D
9
0
4
C
1
D
9
4

Hide quick links: