Installation; Installing - Mitsubishi Electric PKA-A24FA Installation Manual

Hide thumbs Also See for PKA-A24FA:
Table of Contents

Advertisement

2. Installation
location
A
D
2.1. Outline dimensions (indoor unit) (Fig. 2=1)
Select
a proper
position
allowing
the following
clearances
for installation
and mainte-
nance.
(mm)
(inch)
Models
D
H
A
B
C
E
F
235
340
Min. 150
Min. 50
Min. 30
Max. 250 Max. 150
A24, A30
9-1/4
13-3/8
Min,5-15/1(
Min. 2
Min. l-3/16
Max. 10 Min, 5-15/16
235
340
Min. 150
Min. 50
Min. 30
Max. 250 Max. 150
A36
9-1/4
13-3/8
Min,5-15/1(
Min. 2
Min. l-3/16
Max. 10 Min, 5-15/16
W
1400
55-1/8
1680
66-5/32
z_ Warning:
Mount
the indoor
unit
on a ceiling
strong
enough
to withstand
the weight
of the
unit.
w
Fig. 2=1
2.2. Outline
dimensions
(Outdoor
unit)
3. Installing
the indoor
unit
Refer to the outdoor
unit installation
manual.
@
®
Fig. 3=1
3.1. Check the indoor unit accessories
(Fig. 3=1)
The
indoor
unit should
be supplied
with the following
accessories.
PARTNUMBER
ACCESSORY
11@
Wall-fixing
bracket
C2_
Tapping
screw
4 x 35
Insulation
material
(_)
Band
1@
Felt tape
1@
Drain
socket
C7_
Wireless
remote
controller
1@
Remote
controller
holder
1@
Alkali
batteries
_)
Wired
remote
controller
1@
Drain
adaptor
(_)- _) are
QUANTITY
1
12
2
4 (large) + 5 (small)
3
1
1
1
2
1
1
LOCATION OFSETTING
Fixatthe backofthe unit
Set inside
the unit
for PKA-A.FAL
for PKA-A.
FA
stored
in a cut-out
section
of the packing
material
(styrofoam).
[] A24, A30
®
_,_2
.... _2
[] A36
(inch)
3.2. Installing the wall mounting
fixture
(Fig. 3=2)
1) Setting
the wall
mounting
fixture
and
piping
positions
_. Using
the wall
mounting
fixture,
determine
the
unit's
installation
position
and the locations
of the piping
holes
to be drilled.
z./_ Warning:
Before drilling
a hole in the wall, you must consult the building
contractor,
_A_Indoor unit center line
(B_Left drain range
@ Right drain range
@ Hole for tapping screw
(_ Bolt hole
(_ Hole for tapping screw
Contour of the unit
Knockout hole for left rear piping
(i) Rear piping access hole (90-100 mm, 3-9/16 to 4 inch dia.)
Fig. 3=2
d)
2) Drilling
the piping
hole (Fig.
3-3)
_. Use a core
drill
to make
a hole of 90-100
ram, 3-9/16
to 4 inch diameter
in the
wall
in the piping
direction,
at the position
shown
in the diagram
to the left.
_. The
hole
should
incline
so that the outside
opening
is lower
than
the inside
opening.
_" insert
a sleeve
(with
a 90 mm,
3-9/f6
inch
diameter
and
purchased
locally)
through
the hole.
Note:
The purpose
of the hole's inclination is to promote drain flow.
_A_Sleeve
_B_Hole
(C) (Indoors)
_ Wall
(_ (Outdoors)
©
©
Fig. 3=3
®
3