1. Safety
precautions
Before
installing
the
unit,
make
sure
you
read
all the "Safety
precau-
tions".
Please
report
to your
supply
authority
or obtain
their
consent
before
connecting
this equipment
to the power
supply
system.
Describes
precautions
that
must
be observed
to prevent
danger
of injury
or
death
to the user.
z_
Caution:
Describes
precautions
that
must
be observed
to prevent
damage
to the unit.
Z_ Warning:
= Ask a dealer
or an authorized
technician
to install
the unit.
= For
installation
work,
follow
the instructions
in the
Installation
Manual
and
use tools
and
pipe components
specifically
made
for
use with
refrigerant
specified
in the outdoor
unit installation
manual.
• The unit must
be installed
according
to the instructions
in order to minimize
the
risk of damage
from
earthquakes,
typhoons,
or strong
winds.
An incor-
rectly
installed
unit may
fall
down
and cause
damage
or injuries.
= The
unit must
be securely
installed
on a structure
that
can sustain
its weight.
= if the air conditioner
is installed
in a small
room,
measures
must
be taken
to
prevent
the refrigerant
concentration
in the room
from
exceeding
the safety
limit
in the event
of refrigerant
leakage.
Should
leak and
cause
the concentration
limit to be exceeded,
hazards
due to lack of oxygen
in the
room
may
result.
After
installation
work
has been
completed,
explain
the 'Safety
Precautions,"
use,
and maintenance
of the unit to the customer
according
to the information
in the Op-
eration
Manual
and perform
the test run to ensure
normal
operation.
Both the Instal-
lation
Manual
and Operation
Manual
must be given
to the user
for keeping.
These
manuals
must be passed
on to subsequent
users.
(_:
Indicates
which
must be
a part
grounded.
Z_ Warning:
Carefully
read the labels affixed to the main unit,
• Ventilate
the
room
if refrigerant
leaks
during
operation,
if refrigerant
comes
into contact
with
a flame,
poisonous
gases
will
be released.
• All
electric
work
must
be performed
by a qualified
technician
according
to
local
regulations
and the instructions
given
in this
manual.
Use only
specified
cables
for wiring.
• The terminal
block
cover
panel
of the unit
must
be firmly
attached.
Use only
accessories
authorized
by Mitsubishi
Electric
and
ask a dealer
or
an authorized
technician
to install
them.
• The user
should
never
attempt
to repair
the unit or transfer
it to another
loca-
tion.
• After
installation
has
been completed,
check
for refrigerant
leaks,
if refriger-
ant leaks
into the room
and
comes
into contact
with
the flame
of a heater
or
portable
cooking
range,
poisonous
gases
will be released.
installation
(Environment)
Caution:
• Do not use the
unit in an
unusual
environment,
if the
air conditioner
is in-
stalled
in areas
exposed
to steam,
volatile
oil (including
machine
oil), or sulfuric
gas, areas
exposed
to high
salt content
such
as the seaside,
the performance
can be significantly
reduced
and the internal
parts
can be damaged.
• Do not install
the unit where
combustible
gases
may
leak,
be produced,
flow,
or accumulate,
if combustible
gas accumulates
around
the unit,
fire or explo-
sion
may
result.
• Do not keep food,
plants,
caged
pets, artwork,
or precision
instruments
in the
direct
airflow
of the indoor
unit or too close
to the unit,
as these
items
can be
damaged
by temperature
changes
or dripping
water.
• When
the room
humidity
exceeds
80% or when
the drainpipe
is clogged,
wa-
ter may
drip
from
the indoor
unit.
Do not install
the indoor
unit
where
such
dripping
can
cause
damage.
• When
installing
the unit in a hospital
or communications
office,
be prepared
for
noise
and
electronic
interference.
Inverters,
home
appliances,
high-fre-
quency
medical
equipment,
and radio
communications
equipment
can cause
the air conditioner
to malfunction
or breakdown.The
air conditioner
may also
affect
medical
equipment,
disturbing
medical
care, and communications
equip-
ment,
harming
the screen
display
quality.
1.2. Before installation or relocation
Z_ Caution:
• Be extremely
careful
when
transporting
the units.Two
or more
persons
are
needed
to handle
the unit,
as it weighs
20 kg, 44 Ibs or more.
Do not grasp
the
packaging
bands.
Wear
protective
gloves
as you
can injure
your
hands
on the fins
or other
parts.
• Be sure
to safely
dispose
of the packaging
materials.
Packaging
materials,
such
as nails
and
other
metal
or
wooden
parts
may
cause
stabs
or other
injuries.
• Thermal
insulation
of the
refrigerant
pipe is necessary
to prevent
condensa-
tion.
if the refrigerant
pipe is not properly
insulated,
condensation
will be formed.
Place
thermal
insulation
on the pipes
to prevent
condensation,
if the drain-
pipe is installed
incorrectly,
water
leakage
and
damage
to the ceiling,
floor,
furniture,
or other
possessions
may
result.
Do not clean
the air conditioner
unit
with
water.
Electric
shock
may
result.
• Tighten
all flare
nuts to specification
using
a torque
wrench,
if tightened
too
much,
the flare
nut can break
after
an extended
period.
1.3. Before
electric
work
Z_ Caution:
= Be sure
to install
circuit
breakers,
if not installed,
electric
shock
may
result.
= For the power
lines,
use standard
cables
of sufficient
capacity.
Otherwise,
a
short
circuit,
overheating,
or fire may
result.
= When
installing
the power
lines, do not apply
tension
to the cables.
Be sure
to ground
the unit.
if the unit is not properly
grounded,
electric
shock
may result.
Use circuit
breakers
(ground
fault
interrupter,
isolating
switch
(+B fuse),
and
molded
case
circuit
breaker)
with
the specified
capacity,
if the circuit
breaker
capacity
is larger
than
the specified
capacity,
breakdown
or fire may
result.
1.4. Before
starting
the test run
Z_ Caution:
= Turn on the main
power
switch
more than
12 hours before
starting
operation.
Starting
operation
just
after
turning
on the
power
switch
can severely
dam-
age the internal
parts.
• Before
starting
operation,
check
that
all panels,
guards
and
other
protective
parts
are correctly
installed.
Rotating,
hot, or high
voltage
parts
can
cause
injuries.
= Do not operate
the air conditioner
without
the air filter
set in place,
if the air
filter
is not installed,
dust
may
accumulate
and breakdown
may
result.
= Do not touch
any switch
with
wet hands.
Electric
shock
may
result.
= Do not touch
the refrigerant
pipes with
bare hands
during
operation.
• After
stopping
operation,
be sure to wait at least
five minutes
before
turning
off
the main
power
switch.
Otherwise,
water
leakage
or breakdown
may result.
2